<5. Modbus Communication>
5-12
IM 01C25R05-01EN
Address Label used in
DTM
Address Type Access Type
Char/
Date
Read/
Write Enum list
Default
Value
*1
Unit
Valid
Range
IM
Chapter
1879-
1882
Disp User Info
11_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO11“
-
-
3.4.3
1883-
1886
Disp User Info
11_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1887-
1890
Disp User Info
12_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO12“
-
-
3.4.3
1891-
1894
Disp User Info
12_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1895-
1898
Disp User Info
13_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO13“
-
-
3.4.3
1899-
1902
Disp User Info
13_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1903-
1906
Disp User Info
14_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO14“
-
-
3.4.3
1907-
1910
Disp User Info
14_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1911-
1914
Disp User Info
15_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO15“
-
-
3.4.3
1915-
1918
Disp User Info
15_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1919-
1922
Disp User Info
16_1
Holding
Register
USIGN32×2
ASCII
W
-
“INFO16“
-
-
3.4.3
1923-
1926
Disp User Info
16_2
Holding
Register
USIGN32×2
ASCII
W
-
“ ------ “
-
-
3.4.3
1927
Disp % Reso
Holding
Register
USIGN8
-
W
Table 82
0x0000
-
0 to 1
3.4.3
1928
Bar Indicator
Holding
Register
USIGN8
-
W
Table 83
0x0001
-
0 to 1
1929
Pres disp point
Holding
Register
USIGN8
-
W
Table 84
-
-
0 to 4
3.4.3
1930
SP disp point
Holding
Register
USIGN8
-
W
Table 85
-
-
0 to 4
3.4.3
1931
ET disp point
Holding
Register
USIGN8
-
W
Table 86
-
-
0 to 4
3.4.3
1932
Chg power on
info
Holding
Register
USIGN8
-
W
Table 87
0x0001
-
0 to 1
2.2
1933
Disp User Value
Point 1
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1934
Disp User Value
Point 2
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1935
Disp User Value
Point 3
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1936
Disp User Value
Point 4
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1937
Disp User Value
Point 5
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1938
Disp User Value
Point 6
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1939
Disp User Value
Point 7
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1940
Disp User Value
Point 8
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1941
Disp User Value
Point 9
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1942
Disp User Value
Point 10
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1943
Disp User Value
Point 11
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1944
Disp User Value
Point 12
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1945
Disp User Value
Point 13
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
1946
Disp User Value
Point 14
Holding
Register
USIGN8
-
W
Table 88
0x0001
-
0 to 4
3.4.3
*1:
This value is factory default of M range measurement span without order specification.
*2: