beautypg.com

Yokogawa EJX930A User Manual

Page 43

background image

<5. Modbus Communication>

5-12

IM 01C25R05-01EN

Address Label used in

DTM

Address Type Access Type

Char/

Date

Read/

Write Enum list

Default

Value

*1

Unit

Valid

Range

IM

Chapter

1879-

1882

Disp User Info

11_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO11“

-

-

3.4.3

1883-

1886

Disp User Info

11_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1887-

1890

Disp User Info

12_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO12“

-

-

3.4.3

1891-

1894

Disp User Info

12_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1895-

1898

Disp User Info

13_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO13“

-

-

3.4.3

1899-

1902

Disp User Info

13_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1903-

1906

Disp User Info

14_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO14“

-

-

3.4.3

1907-

1910

Disp User Info

14_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1911-

1914

Disp User Info

15_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO15“

-

-

3.4.3

1915-

1918

Disp User Info

15_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1919-

1922

Disp User Info

16_1

Holding

Register

USIGN32×2

ASCII

W

-

“INFO16“

-

-

3.4.3

1923-

1926

Disp User Info

16_2

Holding

Register

USIGN32×2

ASCII

W

-

“ ------ “

-

-

3.4.3

1927

Disp % Reso

Holding

Register

USIGN8

-

W

Table 82

0x0000

-

0 to 1

3.4.3

1928

Bar Indicator

Holding

Register

USIGN8

-

W

Table 83

0x0001

-

0 to 1

1929

Pres disp point

Holding

Register

USIGN8

-

W

Table 84

-

-

0 to 4

3.4.3

1930

SP disp point

Holding

Register

USIGN8

-

W

Table 85

-

-

0 to 4

3.4.3

1931

ET disp point

Holding

Register

USIGN8

-

W

Table 86

-

-

0 to 4

3.4.3

1932

Chg power on

info

Holding

Register

USIGN8

-

W

Table 87

0x0001

-

0 to 1

2.2

1933

Disp User Value

Point 1

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1934

Disp User Value

Point 2

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1935

Disp User Value

Point 3

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1936

Disp User Value

Point 4

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1937

Disp User Value

Point 5

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1938

Disp User Value

Point 6

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1939

Disp User Value

Point 7

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1940

Disp User Value

Point 8

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1941

Disp User Value

Point 9

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1942

Disp User Value

Point 10

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1943

Disp User Value

Point 11

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1944

Disp User Value

Point 12

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1945

Disp User Value

Point 13

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1946

Disp User Value

Point 14

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

*1:

This value is factory default of M range measurement span without order specification.

*2:

Upper case character can be used. Lower-case is translated to upper case.

This manual is related to the following products: