Yokogawa EJX930A User Manual
Page 41
<5. Modbus Communication>
5-10
IM 01C25R05-01EN
Address Label used in
DTM
Address Type Access Type
Char/
Date
Read/
Write Enum list
Default
Value
*1
Unit
Valid
Range
IM
Chapter
1626
Trim Date
Holding
Register
USIGN32
Date
W
-
0x00010164
-
-
1628-
1635
Trim Desc
Holding
Register
USIGN32×4
ASCII
*2
W
-
spaces
-
-
1636-
1639
Trim Who
Holding
Register
USIGN32×2
ASCII
*2
W
-
spaces
-
-
1640-
1643
Trim Loc
Holding
Register
USIGN32×2
ASCII
*2
W
-
spaces
-
-
1644
ET Fixed
Holding
Register
USIGN8
-
W
Table 73
-
-
0 to 1
3.4.2
1645
Fixed ET Val
Holding
Register
FLOAT
-
W
-
20.0
°C
-273 to
1927
3.4.2
1647
Ext SW
Holding
Register
USIGN8
-
W
Table 74
0x0000
-
0 to 1
3.4.5
1648
H/L Swap
Holding
Register
USIGN8
-
W
Table 75
0x0000
-
0 to 1
3.3.7
1649
Low cut
Holding
Register
FLOAT
-
W
-
10.0
%
0 to 20
3.3.6
1651
Low cut mode
Holding
Register
USIGN8
-
W
Table 76
0x0000
-
0 to 1
3.3.6
1751
Disp Out 1
Holding
Register
USIGN8
-
W
Table 80
0x0000
-
With in
enum list
3.4.3
1752
Disp Out 2
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1753
Disp Out 3
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1754
Disp Out 4
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1755
Disp Out 5
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1756
Disp Out 6
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1757
Disp Out 7
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1758
Disp Out 8
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1759
Disp Out 9
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1760
Disp Out 10
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1761
Disp Out 11
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1762
Disp Out 12
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1763
Disp Out 13
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1764
Disp Out 14
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1765
Disp Out 15
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1766
Disp Out 16
Holding
Register
USIGN8
-
W
Table 81
0x00FA
-
With in
enum list
3.4.3
1767
Disp User
Value 1
Holding
Register
FLOAT
-
W
-
0.0
-
-
3.4.3
1769
Disp User
Value 2
Holding
Register
FLOAT
-
W
-
0.0
-
-
3.4.3
1771
Disp User
Value 3
Holding
Register
FLOAT
-
W
-
0.0
-
-
3.4.3
1773
Disp User
Value 4
Holding
Register
FLOAT
-
W
-
0.0
-
-
3.4.3
1775
Disp User
Value 5
Holding
Register
FLOAT
-
W
-
0.0
-
-
3.4.3
*1:
This value is factory default of M range measurement span without order specification.
*2:
Upper case character can be used. Lower-case is translated to upper case.