Page 5
-5-
The RS-485/RS-422
type
The communication method is switched with a change switch.
Dsub 9-pin socket connector's pin assignments are as follows.
Unit’s Connector
: XM3B-0942-132L
Recommended Connector
: XM2A-0901
Recommended Cover
: XM2S-0913
Jack Screw
: XM2Z-0073
Stacking Metal Fittings require #4-40 inch screw.
*1 The VCC output for Pin #6 is not protected against overcurrent. To prevent damage or unit mal-
functions, use only the rated current.
RS422
RS485
.
3.2
RS-485 Isolation Unit
Signal
Name
Direction
Meaning
1
T RMRX
-
Termination
(Receive side:100
Ω)
2
-
-
3
Input/Output Receive/Send DataA(+)
4
NC
-
No connection
5
SG
-
Signal Ground
6
VCC
-
+5V±5% output 0.05A
*1
7
-
-
8
Input/Output Receive/Send DataB(-)
9
T RMTX
-
Termination
(Send side:100
Ω)
Shell
FG
-
Frame Ground
Pin Arrangement
Pin #
RS-485
RDB/SDB
RDA/SDA
RS-485
5
1
9
6
RS-422
Signal
Name
Direction
Meaning
1
T RMRX
-
T ermination
(Receive side:100
Ω)
2
RDA
Input
Receive DataA(+)
3
SDA
Output
Send DataA(+)
4
NC
-
No connection
5
SG
-
Signal Ground
6
VCC
-
+5V±5% output 0.05A
*1
7
RDB
Input
Receive DataB(-)
8
SDB
Output
Send DataB(-)
9
T RMT X
-
T ermination
(Send side:100
Ω)
Shell
FG
-
Frame Ground
Pin Arrangement
Pin #
RS-422
5
1
9
6
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" LT3300 - 5.7 All-in-One HMI" LT3200 - 3.8 All-in-One HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"