Com1 [rs-485 2/4 w] port, com3[rs-485] port, Ethernet communications – Maple Systems Windows CE Embedded 6.0 Professional Edition User Manual

Page 13

background image

9

Chapter 1 – Hardware Configuration

Maple Systems

1010-1016 Rev 00

www.maplesystems.com

COM1 [RS-485 2/4 W] Port, COM3[RS-485] Port

Pin out of DE9S (female) connector

Pin# COM1 [RS-485 2W] COM1 [RS-485 4W] COM3[RS-485 2W]

1

TX/RX -

RX -

2

TX/RX +

RX +

3

TX -

4

TX +

5

Signal Ground

6

TX/RX -

7

8

9

TX/RX +

Ethernet Communications

OMI5000 Series comes equipped with a 10/100BaseT Ethernet port. By default, the product’s Ethernet
port is set to get an IP address from a DHCP server.

 To change the IP address:

1.

From the Windows CE desktop, click the Start button.

2.

Click Settings

3.

Click Network and Dial-up Connections.

4.

Double-click FEC1.

5.

Select the IP Address tab.

6.

Click the Specify an IP address option button.

7.

Enter an IP Address and Subnet Mask. Make sure that the IP Address and Subnet mask are
consistent with the IP addresses that the Open HMI will be connected to.

8.

Enter a Default Gateway if needed.

9.

Select the Name Servers tab.

10.

If required, enter the IP addresses of the Primary and Secondary Domain Name Service
servers.

11.

If required, enter the IP addresses of the Primary and Secondary Windows Internet Naming
Service
servers.

12.

Click the OK button. Then close the Network Connections window