10
ROSS CONTROLS
®
Sizes 8, 12, 30
C
A
B
3
2
1
D-S MONITOR
Wiring Diagram
A B C D E F G H J K
a
b
POWER
SOL. a
POWER
SOL. b
MONITOR
POWER
RESET
SWITCH
FAULT
INDICATOR
D-S MONITOR
Port
Valve Model Number
Avg. C
V
Dimensions inches (mm)
Weight
Size Size w/ Overrides w/o Overrides In-Out Out-Exh.
A
B
C
lb (kg)
8
1/2
3573B4143
3573B4163
3.5
8.5
8.5 (216)
7.2 (184) 16.5 (418) 16.8 (7.6)
8
3/4
3573B5143
3573B5163
4.0
12
8.5 (216)
7.2 (184) 16.5 (418) 16.8 (7.6)
12
3/4
3573B5153
3573B5173
8.0
15
9.0 (229)
8.6 (219) 17.8 (451) 20.5 (9.2)
8
1
3573B6153
3573B6173
4.0
12
8.5 (216)
7.2 (184) 16.5 (418) 16.8 (7.6)
12
1
3573B6163
3573B6183
8.5
19
9.0 (229)
8.6 (219) 17.8 (451) 20.5 (9.2)
12
11/4
3573B7163
3573B7183
9.0
21
9.0 (229)
8.6 (219) 17.8 (451) 20.5 (9.2)
30*
11/4
3573B7153
3573B7173
20
42 12.4 (314) 11.1 (282) 21.8 (553) 39.3 (17.7)
30*
11/2
3573B8163
3573B8183
21
43 12.4 (314) 11.1 (282) 21.8 (553) 39.3 (17.7)
Valves Models without Piping Flanges (For replacement purposes)
8
All
3573B4203
3573B4223
See corresponding size
15.3 (6.9)
12
All
3573B5203
3573B5223
above.
19.0 (8.6)
30
All
3573B7203
3573B7223
37.8 (17.2)
*2 inch port size available on size 30 valves. Order part number 1999H77 flange kit separately.
Series 35 SERPAR
®
Double Valves with
D-S
Monitor
A
C
(4 places)
B
Port 1
(inlet)
3/4 NPSC
electrical
opening
Port 2
(outlet)
H
Momentary Reset Switch
with no power applied.
(supplied by customer)
VALVE OPERATION
Both solenoids must be energized simultaneously to shift the
valve; maintained signal required to keep valve shifted.
WARNING: If monitor must be reset, electrical signals to both
solenoids must be removed to prevent the machine controlled
by the valve from immediately recycling and producing a
potentially hazardous condition.
OPTIONS
Valve Without Piping Flanges: See above.
Valve Without Silencer: Exhaust port has threaded flange only.
Consult ROSS.
Valve Response Time (msec) = M + F • V
See page 18 for response time values.