Sizes 8, 12, 30

C

A

B

3

2

1

D-S MONITOR

Wiring Diagram

A B C D E F G H J K

a

b

POWER

SOL. a

POWER

SOL. b

MONITOR

POWER

RESET

SWITCH

FAULT

INDICATOR

D-S MONITOR

Port

Valve Model Number

Avg. C

V

Dimensions inches (mm)

Weight

Size Size w/ Overrides w/o Overrides In-Out Out-Exh.

A

B

C

lb (kg)

8

1/2

3573B4143

3573B4163

3.5

8.5

8.5 (216)

7.2 (184) 16.5 (418) 16.8 (7.6)

8

3/4

3573B5143

3573B5163

4.0

12

8.5 (216)

7.2 (184) 16.5 (418) 16.8 (7.6)

12

3/4

3573B5153

3573B5173

8.0

15

9.0 (229)

8.6 (219) 17.8 (451) 20.5 (9.2)

8

1

3573B6153

3573B6173

4.0

12

8.5 (216)

7.2 (184) 16.5 (418) 16.8 (7.6)

12

1

3573B6163

3573B6183

8.5

19

9.0 (229)

8.6 (219) 17.8 (451) 20.5 (9.2)

12

11/4

3573B7163

3573B7183

9.0

21

9.0 (229)

8.6 (219) 17.8 (451) 20.5 (9.2)

30*

11/4

3573B7153

3573B7173

20

42 12.4 (314) 11.1 (282) 21.8 (553) 39.3 (17.7)

30*

11/2

3573B8163

3573B8183

21

43 12.4 (314) 11.1 (282) 21.8 (553) 39.3 (17.7)

Valves Models without Piping Flanges (For replacement purposes)

8

All

3573B4203

3573B4223

See corresponding size

15.3 (6.9)

12

All

3573B5203

3573B5223

above.

19.0 (8.6)

30

All

3573B7203

3573B7223

37.8 (17.2)

*2 inch port size available on size 30 valves. Order part number 1999H77 flange kit separately.

Series 35 SERPAR

®

Double Valves with

D-S

Monitor

A

C

(4 places)

B

Port 1

(inlet)

3/4 NPSC

electrical

opening

Port 2

(outlet)

H

Momentary Reset Switch

with no power applied.

(supplied by customer)

VALVE OPERATION

Both solenoids must be energized simultaneously to shift the
valve; maintained signal required to keep valve shifted.
WARNING: If monitor must be reset, electrical signals to both

solenoids must be removed to prevent the machine controlled

by the valve from immediately recycling and producing a

potentially hazardous condition.

OPTIONS

Valve Without Piping Flanges: See above.

Valve Without Silencer: Exhaust port has threaded flange only.

Consult ROSS.

Valve Response Time (msec) = M + F • V

See page 18 for response time values.