beautypg.com

Ross Controls DRIP LEG DRAINS User Manual

New product introduction, Drip leg drains, Ports: 3/4” thru 2

background image

DRIP LEG DRAINS

New Product

Introduction

GENERAL:

The ROSS Drip Leg Drain replaces conventional welded drip legs
through improvements in both performance and serviceability
resulting in increased machine productivity.
The ROSS Drip Leg Drain has a baffling device that increases
the contamination removal efficiency by requiring the air to make
more direction changes than a standard drip leg drain. This
efficiency gain puts less contamination at the point of filtration,
allowing the filter to function longer before maintenance is
necessary.

FEATURES:

• Great for condensation control
• Resistant metal bowl
• Entire unit can be serviced
• No element to be replaced
• Can be installed separately or in-line with FRL unit
• Drain control options include Drain-cock or Ball valve
• Available in NPT or BSPP threads

STANDARD SPECIFICATIONS

Ambient/Media Temperature:
40° to 175° F (4° to 79°C).
Heads: Aluminum.
Bowl Rings: Aluminum.
Inlet Pressure: 15 to 200 psig (1.0 to 13.8 bar).
Filter Drain: Drain-cock or Ball valve.
Seals: Nitrite.
Fluid Media: Compressed air.
Threads: NPT, BSPP.
Model numbers listed with NPT ports.
For BSPP, insert “D” after “01” in the model
number, e.g., RCO12-01D.

General Illustration

Ports: 3/4” thru 2”

Loc

kout

Valv

e

L-O-X

®

Filter

Regulator

Drip Leg Drain

Shut-off
Valve

ROSS EUROPA GmbH

Germany

Fax: 49-6103-74694

[email protected]

ROSS ASIA K.K.

Japan

Fax: 81-427-78-7256

[email protected]

ROSS UK Ltd.

United Kingdom

Fax: 44-121-559-5309

[email protected]

ROSS SOUTH AMERICA Ltda.

Brazil

Fax: 55-11-4335-3888

[email protected]

ROSS CONTROLS INDIA Pvt. Ltd.

India

Fax: 91-44-2625-8730

[email protected]

DIMAFLUID s.a.s.

France

Fax: 33-01-4945-6530

[email protected]

ROSS CONTROLS

(CHINA) Ltd.

China

Fax: 86-21-6915-7960
rosscontrolschina.com

ROSS CONTROLS

U.S.A.

Customer Svs. 1-800-GET-ROSS

Technical Svs. 1-888-TEK-ROSS

www.rosscontrols.com

www.rosscontrols.com

Drip Leg Drain is designed to be used in industrial compressed air system only.

Restrictions in the drain line must be avoided.

The ROSS Drip Leg Drain is recommended where water is likely to accumulate in the air line,
at low points and at the end of the distributions system. Installing a shut-off valve in the air line
before the drip leg drain allows easier service without shutting off the air to the entire system.

Drain Control

Drain-cock and Ball valve