beautypg.com

Ross Controls STAINLESS STEEL SERIES 15 User Manual

Stainless steel l-o-x, Valves, New product introduction

background image

Stainless Steel

L-O-X

®

Valves

Energy Isolation

Port Sizes 1/4 thru 2

www.rosscontrols.com

New Product

Introduction

Manual L-O-X

®

valve shown padlocked in closed position.

The valve can only be locked in the closed position.
Push/pull operation - Push the handle inward to exhaust
downstream air (lockable in this position).
Pull the handle outward in to supply air downstream.

GENERAL:

ROSS L-O-X

®

valves are energy isolation valves and are generally

used as the first valve in a line supplying compressed air to equipment.
Air can be shut off by pushing the L-O-X

®

handle inward; downstream

air is simultaneously exhausted through the L-O-X

®

exhaust port.

Many standards & regulations, e.g., OSHA, require that the valve
be padlocked in this position to prevent handle from being pulled out
inadvertently during maintenance and/or servicing.

FEATURES:

• Easily identified by unique shape
• Corrosion-resistant 316 Stainless Steel construction
• Reliable Fluorocarbon seals withstand contaminant ingression
• Self-draining, washdown suitable design
• Trusted L-O-X

®

performance

• Lockable only in the OFF position
• Large exhaust port for rapid release of pressure
• Standard pressure sensing port with optional pressure switch or

visual indicator

• Simple push/pull of the large handle provides direct manual

operation

• Pressure sensing port allows installation of either the visual

indicator or pressure switch (see page 2) to verify pressure
downstream to the next obstruction is released.

1

2

12

3

10

Valve Operation

VALVE OPEN
When the handle is pulled out,
supply air flows freely from inlet
to outlet and flow to exhaust is
blocked. A detent keeps the
handle in the open position. The
handle is not designed to be
locked in this position, thereby
providing for ready shut-off
when necessary.

1

2

3

VALVE CLOSED
With a push of the handle
inward, the flow of supply air is
blocked and downstream air is
exhausted via the exhaust port
while servicing or maintaining
machinery. Padlock the L-O-X

®

valve in this position to prevent
the handle from being pulled
outward inadvertently to avoid
potential for human injury while
servicing machinery.

1

2

3

Referenced Standards:

All standards are subject to revision. Parties are
encouraged to investigate and apply the most recent
editions of the standards indicated below.

OSHA 29 CFR 1910.147; CSA Z142-10
CSA Z460-05; ISO 13849-1; ISO 14118:2000
EN 1037; ANSI Z244.1- 2003(R2008)
ANSI/PMMI B155.1- 2011, ANSI B11.TR6-2010

• Food and Beverage • Pharmaceutical • Pulp and Paper

• Chemical Processing • Oil and Gas • Off-shore Industries

APPLICATIONS: