Pressure Controlled Pilot Operated Check Valves

TYPICAL APPLICATION

In the schematic diagram at the right, two single PO check valves (Type A or B) are
used in a typical cylinder circuit. Their function is to provide automatic stopping of
the cylinder if either electrical or pneumatic power is lost. This circuit can also be
used for jogging the cylinder as well as providing for an emergency stop.

In certain port sizes the two check valves could be replaced by just one Type C dual
PO check valve. The dual PO check valve contains the functions of two individual
checks in a single compact housing, and eliminates the need to connect externally
the inlet of one check to the pilot of the other.

CHECK
VALVE

CHECK
VALVE

C1

C1

Pilot

Pilot

V1

V1

OPERATING
VALVE

Exhaust

Exhaust

CYLINDER

STANDARD SPECIFICATIONS: For valves on this page.
Ambient/Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered air; 5 micron recommended.
Inlet Pressure: 15 to 150 psig (1 to 10 bar).
Signal Pressure: Must be equal to or greater than inlet.
Port Threads: NPT standard, BSPP. For BSPP threads add a
“D” prefix to the model number, e.g., D2751A2908.

B

C

A

Valve

Port Valve Model Avg. C

V

Dimensions inches (mm)

Weight

Type

Size

Number

(Fully open)

A

B

C

lb (kg)

1/4

2751A2908

2.2

1.5 (38)

3.6 (91)

2.0 (51) 2.3 (1.0)

A

3/8

2751A3908

2.9

1.5 (38)

3.6 (91)

2.0 (51)

2.3 (1.0)

1/2

2751A4915

3.2

1.5 (38)

3.6 (91)

2.5 (64) 2.3 (1.0)

1/4

2751A2903

2.3

3.6 (91)

3.8 (95)

3.1 (79) 1.3 (0.6)

B

3/8

2751A3901

3.8

3.6 (91)

3.8 (95)

3.1 (79)

1.3 (0.6)

1/2

2751A4902

4.0

3.6 (91)

3.8 (95)

3.1 (79) 1.3 (0.6)

1/2

2751A4905

7.7

4.6 (116)

4.4 (112)

3.1 (79) 2.3 (1.0)

B

3/4

2751A5903

9.0

4.6 (116)

4.4 (112)

3.1 (79)

2.3 (1.0)

1

2751A6901

9.0

4.6 (116)

4.4 (112)

3.1 (79) 2.3 (1.0)

1

2751B6904

24

6.7 (169)

6.5 (165)

4.1 (104)

6.0 (2.7)

B

11/4

2751B7901

29

6.7 (169)

6.5 (165)

4.1 (104)

6.0 (2.7)

11/2

2751B8902

29

6.7 (169)

6.5 (165)

4.1 (104) 6.0 (2.7)

3/8

2768C3900

2.9

3.4 (89)

3.7 (94)

2.4 (61)

2.0 (0.9)

C

1/2

2768C4900

3.2

3.4 (89)

3.7 (94)

2.4 (61)

2.4 (1.1)

Dual

3/4

2768C5900

8.5*

4.4 (111)

4.1 (104)

3.0 (76)

3.8 (1.7)

1

2768A6900

8.5*

5.8 (147)

4.1 (104)

3.9 (99)

6.8 (3.1)

*Effective C

V

varies with load and pressure drop. Consult ROSS for specifics on your system.

Type A Single

PO Check Valve

Ports: 1/4 through 1/2

Type B Single

PO Check Valve

Ports: 1/4 through 1

1/2

Type C Dual

PO Check Valve

Ports: 3/8 through 1

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on page 11.

PIPING NOTE FOR TYPE B VALVES

Port 1 should be piped to the cylinder,

and port 2 to the operating valve.

WITHOUT Trapped Pressure Relief Function

• Can be used wherever a high-flow or remotely-controlled checking

function is needed.

• Can be used in a circuit to provide automatic stopping of a cylinder

in the event of the loss of electrical or pneumatic power.

• Also available with an automatic exhausting function, remote and

manual trapped pressure relief function, or solenoid dual pilot
operated check.

Single Pilot Operated Check Valve with

trapped pressure relief illustrated

Series 27 Pilot Operated Check Valves