beautypg.com

Pump - driveshaft - hyd tank figure 4, Figure 5, Figure 6 – Alamo Interstater TS-100A User Manual

Page 20

background image

Interstater (NH TS-100A , 115A , 125A & 135A Asy. Manual) 06/04

© 2004 Alamo Group Inc.

Section 3 - 4

Pump - Driveshaft - Hyd tank

Figure 4

Use

Flatwasher

here

Figure 5

Slotted

Adjusting

Hole

3/8"

square

hole

3/8"

Ratchet

Install Driveshaft, Pump & Tank:
(continued)

10.

Small Pump Belt Adjustment. The belt Guard

is retained with the same bolts that mount the pump
plate and the same bolts that are used to adjust the
drive belt. For now do not install the belt guard. Snug
these bolts for now but do not tighten them

11.

Align driven pulley. The driven pulley on the

small pump will need to be aligned with the drive
pulley below it. Slide the pulley on the pump shaft on
or off to align with the drive pulley on the main
driveshaft. Tighten setscrews in Driven pulley when
aligned.

12.

Install Belt Guard on Small Pump. With the

driven pulley aligned install the belt guard and rein-
stall the retaining nuts.

13.

Adjust the Belt Tension. Look on the mount

plate you will see a 3/8" square hole above the slotted
hole (See Figure 5). Using a 3/8" drive ratchet in the
3/8" hole pull up on the ratchet until the belt is
adjusted. Do not over tighten the belt, it should be
tightened to firm. Holding the tension on the belt
tighten the mounting bolts. You may need to get
someone to help you with this. DO NOT over tighten
the Drive Belt as it could damage the pump. (See
Figure 6)

14.

Prepare Tandem Pump Fittings DO NOT

remove any caps or plugs on hydraulic hoses or
connections until you are connecting them, this will
keep dirt out. The Tandem Pump will need to be
prepared for connecting the hoses. There are fittings
that must be changed. The Fittings in the tandem
pump should already be installed when you receive
it from the factory (See Figure 7). The Pressure Out
Port to LH Wing from outer Tandem half of pump
straight out fitting will need to be change to a 90
degree elbow fitting (See Figure 7 ). The Two large
caps on the tank suction ports will need to be
replaced with two elbow fittings and hose barbs (See
Figure 7, 8 & 9). Coat the fittings that screw into
pumps and tank with a pipe sealer (NOT Teflon
Tape), do not put excess sealer on OD of fittings and
none on ID of fittings (See Figure 7). Install the elbow

Small

Hyd

Pump

for Hyd

Cyl

Supply

Belt

Guard

Pump
Mount

Plate

Small

Pump

In

Suction

Side

Out

Pressure

Side

Figure 6

fitting into the pressure port of the LH Motor Pump (outer pump on tandem pump) with the supplied
elbow (See Figure 9)