background image

19

Warner Electric • 800-825-9050

P-206

819-0519

PC-1225 Clutch Normal Duty

Drawing I-25602

How to Order:
1. Specify Voltage for Item 4.
2. Specify Bore Size for Item 5.
3. Specify left hand or right hand hub for Item 6.

(Bushing enters from magnet side for L.H. hub

and from hub side for R.H.)

Example:
PC-1225 Clutch per I-25602 - 90 Volt, L.H. hub,

1" Bore
These units meet standards set forth in UL508 and

are listed under guide card #NMTR2, file #59164.

These units are CSA certified under file #LR11543.

1

2

3

4

4-1

5

7-1

6-1

6-2

6

(Shipped Assembled)

7

PC-1225

Item

De scrip tion

Part Number

Qty.

1

Armature

5301-111-009

1

2

Autogap Accessory

5201-101-008

4

3

Mounting Accessory

5321-101-001

1

4

Magnet

1

6 Volt

5303-631-005

24 Volt

5303-631-007

90 Volt

5303-631-008

†90 Volt LK Facing

5303-631-001

4-1

Terminal Accessory

5311-101-001

1

5

Bushing*
15/16" to 3" Bore

180-0262 to 180-0295

1

6

Magnet Hub

1

Left Hand

5303-541-001

†Optional LK Facing

5303-541-001

6-1

Collector Ring

5301-749-001

1

6-2

Collector Ring Accessory

5303-101-004

1

7

Brushholder

5300-178-001

1

7-1

Brush

176-0001

4

*See page 38 for specific part numbers.
†Optional LK facing available.