2. Tighten the bushing capscrews, taking a

few turns at a time on each capscrew. As

the capscrews are tightened, the armature

will back away slightly from the magnet.

There should be a clearance of 1/16"

between the armature and magnet when

the capscrews are completely tight.

(See Figure 8)

3. When the bushing is secure on the shaft,

push the armature against the magnet face

(See Figure 9). When the armature

is released, it will spring back about

1/32-inch. This gap will be automatically

maintained for the life of the unit.

(See Figure 3)

Figure 8

Figure 9

E. Mounting the Brushholder

1. The brushholder is mounted on a bracket

which must be furnished by the customer.

The bracket must be firmly secured to

prevent vibration which could cause

improper contact between the brushes

and collector ring.

2. The distance from the centerline of the

shaft to the top of the brushholder should

be 5-3/4". Maintaining this distance will

assure proper spring tension on the

brushes and maximum wear follow-up. A

detailed dimensional drawing is included

with each brushholder.