Air and Contact Probes

The air and contact probes are precision parts, designed to

optimize the response of the Marksman II receiver. The 12 inch air

probe extends its reach and can isolate one leak among multiple

suspect areas. Do not modify the probes in any way and never use

the probes for applications other than described in this manual.

BATTERIES (CHANGING/REPLACING/DISPOSAL)

Two “D” cell alkaline batteries are required (included). When the

batteries near the end of their useful life, the battery LED will flash.

To change the batteries, depress the release tab using a coin or a

screwdriver and slide back the cover. Replace the batteries with

two new “D” cell alkaline batteries. Replace the cover by holding it

in place along the side rails while sliding it forward to engage both

the rear hooks and the front release tab.
Be sure to dispose of batteries in a manner dictated by your

local laws.

IMPORTANT TIPS

Receiver and Emitter Port Openings

The port openings of the receiver and emitter contain a precision

transducer, the heart of the Marksman II ’s operation. During use,

guard against any foreign matter entering this area.
Calibration

The Marksman II has been optimally tuned at our factory and

should require no recalibration during its life under normal

conditions.
LED Display

The LED display allows you to zero in on a steady-state source of

ultrasonic sound, such as when locating an air or vacuum leak or

when using the emitter. Simply watch for a rise or drop in the LEDs

to pinpoint the source of the problem.