TECHNICAL SPECIFICATIONS
Sensitivity ..................................... Detects leaks or defects
through a 0.004 in (0.1 mm)
diameter orifice at 5.0 psig
from a 12 in (30.5 cm) distance
Usage ........................................... Indoor or outdoor
Operating Temperature Range
*
+32 °F to +122 °F (0 °C to
+50 °C)
Storage Temperature Range ........ +14 °F to +140 °F
(-10 °C to +60 °C)
Humidity........................................ 85% RH NC Max.
Altitude.......................................... 6500 ft (2000 m)
Pollution Degree ........................... 2
Dimensions ................................... Width: 4.0 in (10.2 cm)
Depth: 1.5 in (3.8 cm)
Length: 6.0 in (15.2 cm)
Weight .......................................... 3 lb (1.4 kg)
Housing ........................................ Chemical resistant ABS
Battery Life ................................... Approx. 165 hours
Power Requirement ...................... 2 standard “D” cell alkaline
batteries
Power Consumption ..................... 26 mA, typical
Frequency Response ................... 36,000 - 44,000Hz
Circuitry ........................................ Solid state
Overvoltage Category .................. 2
Headphones ................................. Full-sized noise-attenuating
Headphone Connector ................. 3.5 mm phone plug
*
May be operated for a limited time in lower
temperature environments.
19