Many variables can affect the amount of ultrasound generated by
the leakage of gas through an orifice. Such factors include the
pressure/vacuum versus the surrounding environment, how smooth
the edges of the orifice are, the diameter of the orifice, the leak
detector’s distance from the orifice and the presence of airflow,
which may dissipate the ultrasound. As you use the Marksman II,
keep in mind that these factors may affect your ability to detect
ultrasonic leaks.
KIT CONFIGURATIONS AND COMPONENTS
TP-9367 Master Kit Contains
1. The Marksman II ultrasonic receiver. This easy-to-use unit
incorporates audio feedback and five LEDs to indicate the
intensity of the signal. The receiver has a permanently fixed
2-inch directional receiver port, 3.5 mm stereo jack port,
sensitivity adjustment pad and power button.
2. One black rubber 7
3
/
8
inch (18.7 cm) air probe, and a precision-
length contact probe.
3. A full-sized headphone set with a 3.5 mm stereo jack.
4. A rugged carrying case for storage and transportation.
5. The ultrasonic emitter. Sends out a 40kHz pulse for use in
testing seal integrity in non-pressurized vessels.
6. Two “D” cell alkaline batteries.
Ultrasonic Emitter
The emitter gives off a warble output centered at 40kHz. This
output cannot be heard by the human ear. If the red indicator is on,
the unit is emitting.