Below is a summary table of the MP_XX transactions:

Test

Command

Burst size

Data(s)

CBE#(s)

MP_02 Mem

Write

&

Inv. 2 00000000-00000000

0000-0000

MP_03 Mem

Write

&

Inv. 2 00000000-00000000

0000-0000

MP_04 Mem

Write 1

00000000

0000

MP_05 Mem

Read 1

00000000

0000

MP_06 Mem

Read 3

00000000-00000000

00000000

0000-0000

0000

MP_07 Mem

Read 3

00000000-00000000

00000000

0000-0000

0000

MP_08 Mem

Read 2

00000000-00000000

0000-0000

MP_09 Mem

Read 2

00000000-00000000

0000-0000

MP_11 Mem

Write 2

00000000-00000000

1100-1100

MP_13 Mem

Read 2

00000000-00000000

0000-0001

MP_14 Mem

Read 3

00000000-00000000

00000000

0000-0000

0000

MP_15 Mem

Read 3

00000000-00000000

00000000

0000-0000

0000

MP_16 Mem

Read 3

00000000-00000000

00000000

0000-0000

0000

MP_17 Mem

Read 1

00000000

0000

MP_18 Mem

Read 1

00000000

0000

MP_19 Mem

Read 1

00000000

0000

Mem Read (1)

1

00000000

0000

Mem Read (2)

1

00000000

0000

MP_20

Mem Read (3)

1

00000000

0000

MP_23 Mem

Write 4

00000000-00000000
00000000-00000000

0000-0000
0000-0000

MP_24 Mem

Write 1

00000000

0000

MP_25 Mem

Write 1

00000000

0000

Mem Read (1)

1

00000000

0000

Mem Write (2)

1

98765431

0000

MP_28

Mem Write (3)

1

98765430

0000

Mem

Read

(1)

1 00000000 0000

Compliance Test

65