Component Protocol checklist for a master device

1.01 Tests

It is highly recommended that at the beginning the users select only one "Transaction Type" and one

"DEVSEL# Speed" to be sure they can execute all the steps correctly and efficiently before enabling more

Transaction Types. In some cases each added Transaction adds about 16 tests.

Compliance Test

19

Rev. 1.0





There are four sets of transactions that may be executed in these tests, if all the selections have been made
in the options. Otherwise only the selected categories will be tested.

Please note that not all devices are designed to perform all transactions, the user is expected to

be familiar with the specification of the device and enable only the appropriate tests.


The first set is a memory read command followed by a memory write command both with one or more
data phases.

The second set is an I/O read followed by an I/O write command both with one or more data phases.

The third set is a configuration read followed by a configuration write command both with one or more
data phases.