Chapter 7: BitTracer Trace Files

PETracer Software User Manual

74

Teledyne LeCroy

7.8 Errors Bar

BitTracer mode provides a summary of 10b errors (invalid symbols) and disparity errors
in the Errors window. The window shows the total error count and errors per-lane for each
error type. Hyperlinks allow jumps to selected errors.

BitTracer mode also highlights errors:

Invalid symbols have a black background.

Bytes with incorrect running disparity have red borders.