3.

Spark gap should be checked and, if necessary,

adjust to dimension shown.

4.

Clean electrode and grounding rivet with fine file to

assure ground path for spark.

5.

Be certain all slots and holes are clear of cleansing

powder, grease, etc.

BURNER CAPS

Models with Cast Sealed Burners

TO CHECK BURNER-BURNER CAPS:

1.

Turn off power to unit.

2.

Remove cast cap from base.

3.

Be certain the underside of burner cap is clear of

metal shavings, grease, cleansing powder, etc.

4.

Be certain top side of burner base is clear of metal

shavings, grease, cleansing powder, etc.

5.

Spark gap should be checked and, if necessary,

adjusted to dimension shown.

6.

Spark should be visible between electrode wire tip

and bottom side of burner cap. Spark jump to burner

base (not between spark gap) could be due to cracked/

broken ceramic portion of electrode assembly which

requires replacement.