OPERATION AND SERVICE PROCEDURES

71

RC231002 Rev. 3

FIRE OR EXPLOSION

TO AVOID THE RISK OF ELECTRICAL SHOCK,

PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES

IT.

SELECTOR SWITCH

The selector switch is a two (2) position switch used for

"MANUAL" or "AUTOMATIC" bake operation. The selec-

tor switch contacts can be checked for continuity by using

a continuity tester or an ohmmeter set to low ohms range

and following the selector switch contact chart. Power to

the oven must be turned off and the selector switch wiring

removed when checking the contacts for continuity. Ac-

cess to the selector switch contacts can be made by

removing the control panel. NOTE: The selector switch

is not found on models with the ERC.

SELECTOR SWITCH CONTACTS

POSITION

B to 3

B to 4

MANUAL

X

0

AUTO

0

X

O = OPEN X = CLOSED

Selector Switch Circuit

OVEN THERMOSTAT (Not Used On Models With

ERC)

The oven thermostat maintains the correct oven tempera-

tures in the bake, broil, and self-clean operations. The

thermostat is located under the control panel.

In manual and timed bake operations, thermostat contacts

C-BA and 1-2 close completing the bake circuit through the

clock in a timed bake operation, the selector switch, bake

ignitor, and bake gas valve to neutral. Thermostat con-

tacts 1-2 are the cycling contacts that maintain the correct

oven temperatures.

In a boil operation, thermostat contacts C-BR and 1-2 close

completing the broil circuit through the broil ignitor, and

broil gas valve to neutral. Thermostat contacts 1-2 are the

cycling contacts that maintain correct broiling tempera-

tures.

In the self-clean function with oven temperatures below

approximately 700°F., thermostat contacts COM-NO, 7-9

and 1-2 close completing the clean circuit through the latch

switch, the broil ignitor, and broil gas valve to neutral.

After the oven temperature reaches approximately 700°F.,

thermostat contacts COM-NO open and COM-NC close

now completing the circuit through the latch switch, selec-

tor switch, timer contacts, bake ignitor, and bake gas valve

to neutral. Contacts 1-2 cycle to maintain correct self-

cleaning temperatures.

The thermostat contacts can be checked for continuity by

using a continuity tester or an ohmmeter set to the low