28

set to read 120 VAC or higher, attach the meter leads

to the L1 and N wire leads and turn on power to the

range. A voltage reading of approximately 120 VAC

should be indicated. If no voltage is indicated, check

the range wiring. If 120 VAC is indicated shut off

power to the range and reconnect L1 and N wire leads

to the P.C. board terminals.

2.

Disconnect the 20 pin ribbon cable connector from

the P.C. board J2 connector and turn on the power to

the range. Check for voltages at the following pins at

the J2 connector. (See Figure 28.)

PINS

VOLTAGE

2-18

-25 to -35 VDC

6-18

-7 to -9 VDC

8-18

-7 to -9 VDC

10-18

-7 to -9 VDC

14-18

-25 to -35 VDC

15-18

-25 to -35 VDC

2-14

2.0 to 3.6 VDC

DISPLAY BOARD TESTING

Shut off power to the range and remove the display board

from the control panel (refer to Disassembly Procedures).

The function switches and diodes on the display board can

be checked at the J1 connector. Install the clock control

buttons into the display board switch housings. Refer to

Figure 30 for the correct pin number identification.

1.

To check the "MINUTE TIMER" switch and CR3

diode, connect an ohmmeter (set to RX10 or higher)

to pins 8 and 17 at the display board J1 connector and

press the minute timer button. Reverse the ohmme-

ter leads and again press the "MINUTE TIMER"

button. On reading should indicate infinite ohms and

the other reading should indicate low ohms (the diode

conduction resistance and closed minute timer switch).

If a zero (0), low or infinite ohms reading is indicated

with the meter leads connected in both directions, the

display board should be replaced.

2.

To check the "COOK/CLEAN TIME" switch and the

CR5 diode, connect the ohmmeter leads to pins 10

and 16 at the display board J1 connector and press

the "COOK/CLEAN TIME" button. Reverse the meter

leads and again press the "COOK/CLEAN TIME"

button. One reading should indicate infinite ohms

and the other reading should indicate low ohms (the

diode conduction resistance and closed "COOK/

CLEAN TIME" switch). If a zero, low, or infinite ohms

reading is indicated with the meter leads connected in

both directions, the display board should be replaced.

3.

To check the "STOP TIME" switch and the CR5

diode, connect the ohmmeter leads to Pins 6 and 16

at the display board J1 connector and press the

"STOP TIME" button. Reverse the meter leads and

again press the "STOP TIME" button. One (1)

reading should indicate infinite ohms and the other

reading should indicate low ohms (the diode conduc-

tion resistance and closed STOP TIME switch). If a

zero (0), low or infinite ohms reading is indicated with

the meter leads connected in both directions, the

display board should be replaced.

4.

To check the "UP" switch and the CR4 diode, connect

the ohmmeter leads to Pins 8 and 20 at the display

board J1 connector and press the "UP" button. Re-

verse the meter leads and again press the "UP"

button. One reading should indicate infinite ohms

and the other reading should indicate low ohms (the

diode conduction resistance and closed "UP" switch).

If a zero (0), low, or infinite ohms reading is indicated

with the meter leads connected in both directions, the

display board should be replaced.

5.

To check the "DOWN" switch and the CR4 diode,

connect the ohmmeter leads to Pins 6 and 20 at the

display board J1 connector and press the "DOWN"

button. Reverse the meter leads and again press the

"DOWN" button. One reading should indicate infinite

ohms and the other reading should indicate low ohms

(the diode conduction resistance and closed "DOWN"

switch). If a zero (0), low, or infinite ohms reading is

indicated with the meter leads connected in both

directions, the display board should be replaced.

6.

To check the "CLOCK/CANCEL" switch and the CR2

and CR4 diodes, connect the ohmmeter leads to Pins

10 and 20 at the display board J1 connector and press

the "CLOCK/CANCEL" button. Reverse the meter

leads and again press the "CLOCK/CANCEL" button.

One reading should indicate infinite ohms and the

other reading should indicate low ohms (CR2 and

CR4 diode conduction resistance and closed "CLOCK/

CANCEL" switch). If a zero (0), low, or infinite ohms

reading is indicated with meter leads connected in

both directions, the display board should be replaced.

7.

The CR1 diode can be checked by connecting the

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

This manual is related to the following products: