OPERATION AND SERVICE PROCEDURES

Electronic Range Control (ERC) (Models w/Two Piece Control)

RC231002 Rev. 3

36

TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

TERMINALS

/PINS

CIRCUIT TESTED

APPROXIMATE

OHMS READINGS

J1-1 TO J1-2
J1-1 TO J1-3
J1-5 TO J1-6
J1-7 TO J1-8
E1 TO E2
E4 TO E5
E6 TO E7

BAKE RELAY COIL
BROIL RELAY COIL
TRANSFORMER SECONDARY WINDING
TRANSFORMER SECONDARY WINDING
TRANSFORMER PRIMARY WINDING
BROIL RELAY CONTACT
BAKE RELAY CONTACT

560 OHMS
560 OHMS
5-7 OHMS
2-4 OHMS
120-150 OHMS
INFINITE OHMS (OPEN)
INFINITE OHMS (OPEN)

Figure 37

Relay Board Schematic

NOTE: Check each transformer terminal (J1-5, J1-6, J1-

7, J1-8, E1 and E2) in turn to ground terminal E3. All

readings must be infinite (OPEN).

Figure 36

Relay/Power Supply Circuit Board

Terminal/Pin Locations