beautypg.com

Operation and service procedures, Slide in models) – Amana RSS User Manual

Page 30

background image

OPERATION AND SERVICE PROCEDURES

(SLIDE IN MODELS)

29

RC231002 Rev. 3

ohmmeter leads to Pins 10 and 17 at the display board

J1 connector and then reversing the ohmmeter leads.

One reading should indicate infinite ohms and the

other reading should indicate low ohms (CR1 diode

conduction resistance). If a zero (0), or infinite ohms

reading is indicated with the meter leads connected in

both directions, the display board should be replaced.

P.C. BOARD/DISPLAY BOARD

INTERCONNECT CABLE

The 20 pin ribbon cable that connects the Clock/Timer P.B.

board to the display board can be checked for continuity

using an ohmmeter set to the low ohms scale. Refer to

Figure 29 and 30 for correct pin identification. If an open

wire is indicated in the ribbon cable, the cable should be

replaced.

The information on Page 54 pertains to the 20 wire ribbon

cable which connects the P.C. board to the display board.

A switch was added to each wire of the ribbon cable to

demonstrate the results if that switch/wire opened. This

information may be useful in diagnosing and repairing

some display/control problems on the digital clock/timer.

Figure 58 - Display Board

Figure 59 - Display Board - Rear View