PROBLEMS
POSSIBLE CAUSE
CORRECTION
E. Display operates
normally. Bake or broil
relays do not operate.
1.
2.
Open ground wire for E.R.C.
relay drive return or relay
board relay drive return.
No E.R.C. relay drive
voltage.
1.
Check continuity of green gr
and relay/power supply boar
If no continuity, repair or rep
good, proceed to Step 2.
Check for 24 VDC drive volt
when E.R.C. is programmed
Check bake relay drive votla
J1-5. Check broil relay drive
anf J1-5. If no voltage is ind
voltage is indicated, proceed
3.
4.
No relay drive voltage to
relay/power supply circuit
board.
Open bake/broil relay coil.
3.
Check for 24 VDC relay drive
E.R.C. is programmed for ba
bake relay drive voltage at re
Check broil relay drive voltag
J1-2. Check broil relay board
no voltage is indicated proce
Check bake/broil relay coil fo
wire leads from relay board t
ohmmeter to the terminals. C
board terminals J1-1 and J1-
relay board terminals J1-3 an
be approximately 560 ohms.
relay board.