beautypg.com

Operation and service procedures – Amana RSS User Manual

Page 64

background image

OPERATION AND SERVICE PROCEDURES

63

RC231002 Rev. 3

Figure 65

The ignitor may still be defective even though conti-

nuity is indicated and it glows when the oven is set for

bake, broil, or clean function. A more exact test can

be made to measure the ignitor current with the oven

operating. An ammeter should be inserted in series

with one (1) lead of the ignitor or an amprobe can be

attached to the lead to check the amount of current

flowing through the ignitor circuit. With the oven

turned on and the ignitor glowing red, a current

reading of approximately 3.2 - 3.6 amps should be

indicated. The ignitor can also be removed and

bench tested, using the current test method and an

AC jumper or test cord connected to the ignitor leads.

ELECTRIC GAS VALVE

The bake and broil dual gas valve supplies the gas flow to

the bake or broil burners. The valve contains bi-metalic

arms attached to the valve seats and are wound with a

small electric heater coil. When a current range of

approximately 3.2 - 3.6 amps flows through the bake or

broil circuit, the bi-metalic arm is heated causing it to flex

or bend, allowing gas to flow to the burner where it is ignited

by the burner ignitor. The gas valve is located behind the

storage drawer.

ELECTRIC GAS VALVE TEST WITH VOLT/OHM

METER

1.

Disconnect electricity. (Disconnect plug or power

cord.)

2.

Remove the two (2) wire terminals from Point A for

testing "BAKE" portion of gas valve or Point B for

testing "BROIL" portion of gas valve.

3.

Set volt/ohmmeter on the RX1 ohms scale (zero (0)

the meter).

4.

Attach a meter lead to each of the terminal studs on

the portion of the valve to be tested.

TO AVOID THE RISK OF ELECTRICAL SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

5.

If the meter does not show an "OPEN" circuit, the gas

valve is operative.

6.

Reattach the two (2) wire terminals removed from

Point A or Point B on the gas valve.

Figure 66

SELECTOR SWITCH

The selector switch is a two (2) position switch used for

"MANUAL" or "AUTOMATIC" bake operation. The selec-

tor switch contacts can be checked for continuity by using

a continuity tester or an ohmmeter set to the low ohms

range and following the selector switch contact chart.

Power to the oven must be turned off and the selector

switch wiring removed when checking the contacts for

continuity. Access to the selector switch contacts can be

made by removing the control panel. NOTE: The selector

switch is not found on models with the ERC.

SELECTOR SWITCH CONTACTS

POSITION

B to 3

B to 4

MANUAL

X

0

AUTO

0

X

O = OPEN X = CLOSED

This manual is related to the following products: