OPERATION AND SERVICE PROCEDURES

75

RC231002 Rev. 3

TROUBLESHOOTING GUIDE

PROBLEMS

POSSIBLE CAUSE

CORRECTIO

1.

No Self-Clean

A.

B.

C.

Controls not set properly.

Faulty latch switch.

Oven or broiler burner does not
turn on.

A.

B.

C.

Turn selector
door latch to
oven heat co
Oven indicato
not refer to n
models do no

Check for 12
with the door
voltage is pre
is OK; if not,

Check unit in
insure both f
both function
are OK proce
check apprip
procedure in

SELF-CLEAN CONTROLS

The self-Clean controls for self-cleaning the lower compartment consist of the clock timer, the clean portion of the

thermostat, and the gas valve assembly.

PROBLEMS

POSSIBLE CAUSE

CORRECTION

1.

Oven Burner/Broil Burner will
not turn on. "Selector" switch set
on BAKE/BROIL. Thermostat set
at 350°/Broil. Door latch in cook
position.

NOTE: The flat type ignitor
used in these models has an
operating current range of from
3.2 amps A.C. to 3.6 amps A.C.
The gas valve is calibrated to
open at slightly over 3.2 amps,
since the ignitor will be hot
enough to ignite any gas flowing
from the burner. The current
can be checked using a
clamp-on ammeter or an in-line
ammeter. If the current does not
reach 3.2 amps, replace the
ignitor.

A.

B.

C.

D.

E.

F.

No 120 VAC to range.

Inoperative ignitor.

Inoperative gas valve.

Inoperative selector switch.

Inoperative thermostat.

Faulty wiring.

A.

B.

C.

D.

E.

Check electric

Check ignitor
page --. Rep

Check gas va
on page --. R

Check selecto
instructions on
switch.

Check thermo
on page --. R

Check wiring
diagram and
connections a

2.

Gas valve opens but
Oven/Broiler burner does not
ignite.

A.

B.

BAKE/BROIL igniotr positioned
too far from burner.

Incorrect adjustement/or
incorrect burner orifice on broil
burner. (LP GAS).

A.

B.

Reposition BA
the burner.

Adjust univers
Install correct

OVEN CONTROLS

The oven controls consist of a thermostat, selector switch, gas vlave and a 120 VAC electric ignitor to provide ignition

for the gas at the oven burner and broiler burner.

TO AVOID THE RISK OF ELECTRICAL SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER

BEFORE SERVICING, UNLESS TESTING REQUIRES IT.