INSTALLATION INSTRUCTIONS

RC231002 Rev. 3

20

After the oven has cycled for 25 to 30 minutes, note the

temperature that the oven cycles ON and OFF. For

example, at 350° setting the oven cycles between 335° and

355°. This provides a mean or average temperature of

345°F., well within the ±25°F specification.

GAS PRESSURE

Correct ignition and operation of the burners are dependent

upon adequate gas pressure. The regulator is designed to

provide pressure of approximately six (6) inches water

column pressure (WCP) for natural gas and approximately

eleven (11) inches for WCP for liquid propane (LP) gas,

provided the universal type gas regulator and gas valves

have been correctly set up for the type gas employed.

These pressures therefore require that the minimum supply

pressure to the regulator must be at least six (6) inches

WCP for natural gas and eleven (11) inches WCP for LP

gas, with maximum pressure not to exceed fourteen (14)

inches WCP.

MEASURING GAS PRESSURE

Equipment for measurement of gas pressure varies from

pressure meters and gauges to the relatively simply and

most commonly used manometer. If it is used, follow the

directions supplied with the unit. The following informations

covers the use of a manometer.

A manometer is simply a U-shaped tube of clear plastic or

glass (see illustration). A scale in inches is located between

the two (2) legs of the "U". In use, the tube is filled with

sufficient water to achieve a level at "0" inches. One end

of the tube is connected to the range manifold or gas valve

orifice while the other end of the tube or leg is open. When

gas pressure is applied, the water on the gas side of the tube

is pushed down and the water in the other leg rises up

against the atmospheric pressure on the open end. The

sum of the readings below the zero level and above the

level will provide the gas pressure in inches water column,

or the water column height which the gas pressure will

support against the atmospheric pressure on top of the

water column. The manometer therefore indicates gas

pressure in inches water column. This conforms with the

gas specifications for gas appliances which are given as

inches WCP or inches water column pressure.

USING THE MANOMETER

The usual procedure for taking the pressure reading is to

connect the tubing to one of the gas valve orifice hoods and

turn on the valve. A full load reading should be taken by

turning on all of the top burners and the oven burner to

assure that the pressure under a full load is adequate.

Figure 33 shows four (4) inches water column pressure

(WCP), two (2) inches above and two (2) inches below the

zero level.

Figure 33 - The Mannometer