beautypg.com

Ee69 ee6c, Ed5d – IAI America XSEL-S User Manual

Page 37

background image

4.

Appendix

31

Monitor LED

Contents

Cause and Remedy

EE69

EE6C

24V I/O Error

DO Output Current Error

It is generated when the +24V power for I/O is not

supplied. Check the power supply.

(How to start up the controller without connecting

the I/O 24V power)

Set the I/O parameter No.10 to 13 corresponding

to the standard or extended I/O board to “0”. (Note)

I/O cannot be used.

ED5D

Fieldbus Error

This occurs when the network connection is not

established.

Check the parameters on XSEL and the

parameters on PLC.

(Way to boot the controller without connecting to

EtherNet/IP)

Set both the I/O parameter No.18 to “0”.



Other Alarm Codes Related to EtherNet/IP

Ɣ Message Level Error

No.

Error name

Contents / Counteractions

A6B

Fieldbus Error

(FBRS Link Error)

FBRS Link Error was detected.

Ɣ Operation Cancel Level Errors

No.

Error name

Contents / Counteractions

B1B

EtherNet Non-Closed Socket Open

Error

Without closing the socket, it was tried to get open again.

B1C

Error of EtherNet Being Used by Other

Task

The channel already open in another task is tried to get open

again.

B1D

EtherNet Non-Open Error

The channel that is not open in its own task is tried to be used.

B1E

EtherNet WRIT Execution Duplicated

Error

WRIT Command was executed by multiple tasks at the same

time to the same channel, or WRIT Command was executed

again without CLOS Command ĺ OPEN Command not being

executed after WRIT was failed (due to communication error,

etc.).

B1F

EtherNet Job Busy Error

A new task was tried to be stared while the EtherNet mail box

control job is busy.

B20

EtherNet Initializing Device Used Error

EtherNet system tried to be used while the initializing of

EtherNet devices is not completed. Check I/O Parameters such

as No.123 to 159, 14, 15, and so on depending on the purpose

of use.

B21

EtherNet IP Address Error

The conditions described below will cause error under a normal

way to use.

Assuming the IP address (H) (1

st

Octet) to IP address (L) (4

th

Octet) are expressed as IP_H, IP_MH, IP_ML and IP_L, the

conditions to be defined as error are;

IP_H ” 0 or IP_H = 127 or IP_H > 255

or IP_MH < 0 or IP_MH > 255

or IP_ML < 0 or IP_ML > 255

or IP_L ” 0 or IP_L • 255

Check I/O Parameters No.132 to 135, 149 to 152, 154 to 157 or

the integer variable connected IP address indicated in IPCN

Command.

B22

EtherNet Port No. Error

Self-Port Number [1025 or Self-Port Number] 65535 or

Duplication of self-port number or Connected port number at

client ” 0 or Connected port number at client > 65535 or

Connected port number at server [0 or Connected port number

at server] 65535

will cause an error.

Check I/O Parameters No.144 to 148, 159, 153, 158 or the

integer variable connected Port Number indicated in IPCN

Command.

This manual is related to the following products: