Ee69 ee6c, Ed5d – IAI America XSEL-S User Manual
Page 37

4.
Appendix
31
Monitor LED
Contents
Cause and Remedy
EE69
EE6C
24V I/O Error
DO Output Current Error
It is generated when the +24V power for I/O is not
supplied. Check the power supply.
(How to start up the controller without connecting
the I/O 24V power)
Set the I/O parameter No.10 to 13 corresponding
to the standard or extended I/O board to “0”. (Note)
I/O cannot be used.
ED5D
Fieldbus Error
This occurs when the network connection is not
established.
Check the parameters on XSEL and the
parameters on PLC.
(Way to boot the controller without connecting to
EtherNet/IP)
Set both the I/O parameter No.18 to “0”.
Other Alarm Codes Related to EtherNet/IP
Ɣ Message Level Error
No.
Error name
Contents / Counteractions
A6B
Fieldbus Error
(FBRS Link Error)
FBRS Link Error was detected.
Ɣ Operation Cancel Level Errors
No.
Error name
Contents / Counteractions
B1B
EtherNet Non-Closed Socket Open
Error
Without closing the socket, it was tried to get open again.
B1C
Error of EtherNet Being Used by Other
Task
The channel already open in another task is tried to get open
again.
B1D
EtherNet Non-Open Error
The channel that is not open in its own task is tried to be used.
B1E
EtherNet WRIT Execution Duplicated
Error
WRIT Command was executed by multiple tasks at the same
time to the same channel, or WRIT Command was executed
again without CLOS Command ĺ OPEN Command not being
executed after WRIT was failed (due to communication error,
etc.).
B1F
EtherNet Job Busy Error
A new task was tried to be stared while the EtherNet mail box
control job is busy.
B20
EtherNet Initializing Device Used Error
EtherNet system tried to be used while the initializing of
EtherNet devices is not completed. Check I/O Parameters such
as No.123 to 159, 14, 15, and so on depending on the purpose
of use.
B21
EtherNet IP Address Error
The conditions described below will cause error under a normal
way to use.
Assuming the IP address (H) (1
st
Octet) to IP address (L) (4
th
Octet) are expressed as IP_H, IP_MH, IP_ML and IP_L, the
conditions to be defined as error are;
IP_H 0 or IP_H = 127 or IP_H > 255
or IP_MH < 0 or IP_MH > 255
or IP_ML < 0 or IP_ML > 255
or IP_L 0 or IP_L 255
Check I/O Parameters No.132 to 135, 149 to 152, 154 to 157 or
the integer variable connected IP address indicated in IPCN
Command.
B22
EtherNet Port No. Error
Self-Port Number [1025 or Self-Port Number] 65535 or
Duplication of self-port number or Connected port number at
client 0 or Connected port number at client > 65535 or
Connected port number at server [0 or Connected port number
at server] 65535
will cause an error.
Check I/O Parameters No.144 to 148, 159, 153, 158 or the
integer variable connected Port Number indicated in IPCN
Command.