3. XSEL-R/S/RX/SX/RXD/SXD
27
3.6 Connection to Network
EtherNet/IP occupies EtherNet Port No.44818 and 2222.
The connection of EtherNet/IP is established by indicating the port 44818 in the IP address of
XSEL Controllers in EtherNet/IP software.
Caution Please note that Port No.2222 (UDP Port) and 44818 (TCP Port and UDP Port)
must be open for use by any firewall configuration.
Caution In case EtherNet/IP Remote IO Communication and TCP/IP Message
Communication are being used at the same time, the reset command from the
network configurator may not be executed properly.
If an execution of the reset from the configurator is required, temporarily
inactivate TCP/IP Message Communication (by setting 0 to I/O Parameter No.
129 ̌Network Attribute 10̍), and conduct the reset. (Make sure to put back the
setting after reset is done.)
3.7 Standard I/O Ports of XSEL Controller
It is available to add special functions beside the general-purposed input and output in the
standard I/O ports of XSEL Controllers.
=
Refer to XSEL-R/S/RX/SX/RXD/SXD Controller Operation Manual for the details.?
[Settings of Standard I/O Ports at Delivery]
㩷
㩷
㩷
㩷
㩷
㩷
㩷
㩷
㩷
㩷
㩷
㩷
(Note) Number of standard I/O ports is:
•
Input 000 to 299 (300 points max.)
•
Output 300 to 599 (300 points max.)
Be careful of the number of I/O ports when using EtherNet/IP and PIO together.
Input Port
Output Port
Port
No.
Function
Port
No.
Function
000
Program Start
300
Alarm Output
001
Universal Input
301
Ready Output
002
Universal Input
302
Emergency Stop Output
003
Universal Input
303
Universal Output
004
Universal Input
304
Universal Output
005
Universal Input
305
Universal Output
006
Universal Input
306
Universal Output
007
Program Specification
(LSB)
307
Universal Output
008
Program Specification
308
Universal Output
009
Program Specification
309
Universal Output
010
Program Specification
310
Universal Output
011
Program Specification
Indicate startup
program
number with in
binary
311
Universal Output
012
Program Specification
312
Universal Output
013
Program Specification
(MSB)
313
Universal Output
014
Universal Input
314
Universal Output
015
Universal Input
315
Universal Output
• •
•
• •
•