beautypg.com

Xsel-r/s/rx/sx/rxd/sxd 22 – IAI America XSEL-S User Manual

Page 28

background image

3. XSEL-R/S/RX/SX/RXD/SXD

22

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

17

Network I/F Module 1

Fix-Allocated Output Port Start

No.

-1

-1 to 6999

4000

300+(Multiples of 8)(300 to 599)

4000+(Multiples of 8)(4000 to 6999)

[Unavailable when it is negative figure]

18 Network I/F Module 1

Error Monitor

1

0 to 5

1

0: No Monitoring (Not to use Network I/F

Module 1)

1: Monitoring

120 Network Attribute 1

640001H

0 to

FFFFFFFFH

Opti-

onal

Bit 16 to 23:

Value of Link Timeout at initializing

(Example) Default 64H = 10sec

Bit 28 to 31: Network I/F Module 1

Input port data select for link error

(0: Clear, 1: Hold)

132 Network I/F Module 1

Self IP Address (H)

192

1 to 255

192 * Prohibited to set to 0 and 127

133 Network I/F Module 1

Self IP Address (MH)

168

0 to 255

168

134 Network I/F Module 1

Self IP Address (ML)

0

0 to 255

0

135 Network I/F Module 1

Self IP Address (L)

1

1 to 254

1

* Prohibited to set to 0 and 255

136 Network I/F Module 1

Subnet Mask (H)

255

0 to 255

255

137 Network I/F Module 1

Subnet Mask (MH)

255

0 to 255

255

138 Network I/F Module 1

Subnet Mask (ML)

255

0 to 255

255

139 Network I/F Module 1

Subnet Mask (L)

0

0 to 255

0

140 Network I/F Module 1

Default Gateway (H)

0

0 to 255

0

141 Network I/F Module 1

Default Gateway (MH)

0

0 to 255

0

142 Network I/F Module 1

Default Gateway (ML)

0

0 to 255

0

143 Network I/F Module 1

Default Gateway (L)

0

0 to 255

0

225 Network I/F Module Control

*7

00H to 37H

07

Bit 0 to 3:

Type of Network I/F Module Control 1

0: Not Mounted

6: EtherCAT

7: EtherNet/IP

Bit 4 to 7:

Type of Network I/F Module Control 2

0: Not Mounted

1: CC-Link

2: DeviceNet

3: PROFIBUS

227 Network I/F Module 1

Baud Rate

0

0 to 4

0

• At EtherNet/IP:

(0: Autonegotiation,

1: 10Mbps (Half-duplex),

2: 10Mbps (Full-duplex),

3: 100Mbps (Half-duplex),

4: 100Mbps (Full-duplex))

231 Network I/F Module 2

Remote Input Ports

0

0 to 256

0 8 port unit

232 Network I/F Module 2

Remote Output Ports

0

0 to 256

0 8 port unit

233 Network I/F Module 2

Extension Input Port Start No.

-1

-1 to 299

1000 to 3999

-1

0+(Multiples of 8)

or

1000+(Multiples of 8)

[Ineffective when -1 is selected]

This manual is related to the following products: