Caution in Handling

1. Make sure to follow the usage condition, environment and specification

range of the product.

Operaton out of the guarantee could cause a drop in performance or malfunction of the

product.

2. Back and forth operation in a short distance may cause wear of grease.

If the actuators are moved back and forth continuously over a short distance of 30 mm or

less, grease film may run out. As a guide, move the actuators back and forth repeatedly for

around 5 cycles over a distance of 50 mm or more after every 5,000 to 10,000 cycles. Keep

using the actuators with the grease worn out may cause malfunction.

3. Make sure to attach the actuator properly by following this operating

manual.

Using the product with the actuator not being certainly retained or affixed may cause

abnormal noise, vibration, malfunction or shorten the product life.

Warning: Do not get closer than 30cm if you are a person who needs a support of a

medical device such as a pacemaker. This actuator uses high-performance

rare-earth permanent magnets. Therefore an unexpected operation may be

caused to a medical device especially when using such a device such as a

pacemaker.

Caution:

Do not attempt to get a magnetic card close to the product. Having a magnetic

storage medium close to the product may disable the medium by destroying data.

Do not attempt to get a precision instrument such as an electric watch close to the

product. Doing so may cause a trouble to the instrument