4. Caution for Operation (Finger Operations)

31

4� Caution for Operation (Finger Operations)

[1] Finger Stroke

The design stroke of the two- finger type is a sum of travel distances of both fingers. In other

words, the travel distance of one fingers is one-half the design stroke.

[2] Home-Return Direction

The side of that the fingers are open (closer to the side cover) is defined as the home position.

[3] Position Specification caution

The travel distance of each finger from its home position toward the closing side is defined as the

position value.

(Max. position value indication = 1/2 of stroke)

[4] Speed/acceleration Commands

Speed/acceleration commands are specified based on a value per finger. The relative speed and

acceleration of the two-finger type is twice the command value.

[5] Indication of Pressing Operation Direction

For the pressing to inner direction, set the value adding a positive value to the position value. For

the pressing to outer direction, set the value adding a negative value to the position value.

Home-Return Direction

Home position (Position = 0)

Stroke + 2mm
Stroke + 3.5mm

Operation complete position for stroke value (Position = Stroke value)

Home Position (0mm)

to

2mm to 3.5mm