Connecting with controller – IAI America RCD-RA1D User Manual
Page 25

7. Connecting with Controller
19
7. Connecting with Controller
Both for the controller itself and for the connection cable between the controller and RCD (this controller), use a
dedicated IAI controller and dedicated connection cable.
This section explains the wiring method for a single axis.
�
If the dedicated connection cable cannot be secured, reduce the load on the cable by allowing it to deflect only
by the weight of the cable or wire it in a self-standing cable hose, etc., having a large radius.
�
Do not cut and reconnect the dedicated connection cable for extension or shorten the cable.
�
Do not pull on the dedicated connection cable or bend it forcibly.
�
The actuator cable coming out of the motor unit is that for fixing.
Fix the cable so it would not be bent repeatedly.
Please consult with IAI if you require a different kind of cable than the one supplied.
RCD-XX
Dedicated connection cable
(connects controller and RCD)
Dedicated controller
• DSEP
Dedicated connection cable
Motor-encoder cable: CB-CA-MPA***
Motor-encoder cable robot cable: CB-CA-MPA***- RB
*) *** indicates the cable length. Up to 20m can be specified.
Example) 080 = 8 m
r=84mm or mere (Movable Use)
Robot cable
Standard cable
r=84mm or mere (Fixed Use)