2. Specification

11

(5) Current Limit Value and Pressing Force

Current Limit Value and Pressing Force

1.05

2.04

3.02

4.01

4.99

5.98

0.41

0.85

1.28

1.72

2.16

2.60

0

1

2

3

4

5

6

7

0%

10%

20%

30%

40%

50%

60%

70%

80%

Current Limit Value (%)

Pressing Force

(N

)

Caution: (1) The relation of the pressing force and current limiting value is a reference. There will be a little

variance in the actual pressing force.

(2) If the current limiting value is low, the pressing force may largely vary.

(3) The movement speed at the pressing operation is fixed to 5mm/s.

The graph, shows the values when pressing at 5mm/s, and it differs if the speed changes.