Sa su timer 1 on we off – Securitron DT-7 User Manual
Page 3

PN# 500-11800
Page 3
Rev. C, 02/11
relay is showing 'off'. Why doesn't it turn on?" The answer is that the DT-7 does not check
what time it is and then look to see if it is "supposed" to be on or off. It just advances its clock,
minute by minute, and when it encounters an instruction, it executes the instruction. On initial
set-up, use the test button to put the unit in the desired initial state.
If an on and off instruction both occur at exactly the same time and day, the off instruction
will be executed and the on instruction will be ignored. An instruction is erased by
incrementing the hours, minutes, and day buttons to restore the horizontal (null) lines. Note
that momentarily pressing the reset detent will eliminate all program data from the unit as well
as eliminating the time setting. The reset detent has the same effect as removing all power
(including the battery) from the unit.
FIG. 2: TIME SETTING AND PROGRAMMING
Timer
Day
h+
m+
Timer
Day
h+
m+
DAY OF WEEK
MODULE STATUS
HOLD DOWN
TO SET TIME
INCREMENTS DAYS
TEST BUTTON: MANUALLY
CHANGES MODULE STATUS
(ON OR OFF)
TIME OF DAY
INCREMENTS
MINUTES
INCREMENTS
HOURS
DISPLAY MODULE: OPERATING MODE AND TIME SETTING
DISPLAY MODULE: PROGRAMMING MODE
INSTRUCTION
FOR SATURDAY
AND SUNDAY
TIME RELAY WILL
OPERATE (4:40 PM)
INCREMENTS DAYS AND
CALLS UP BLOCK PROGRAMMING
RETURN TO
OPERATING MODE
PRESS TO ENTER
PROGRAMMING
MODE AND TO
INCREMENT
INSTRUCTIONS
1 0F 6
INSTRUCTIONS
TO OPERATE RELAY
AT PROGRAMMED
TIME AND DAY
16:40
SA SU
TIMER
1 ON
WE
OFF
11:05
Reset
ERASES TIME
AND PROGRAM
Reset
BLOCK
INCREMENTS
MINUTES
INCREMENTS
HOURS