Securitron SAM User Manual
Page 13

PN# 500-10440
Page 13
Rev. F, 02/12
8 MAGNALOCK MAINTENANCE
8.1 Visual Inspection
Check the strike assembly for proper gap, suspension and free movement. Tighten strike
adjustment screws as required.
Check for build-up of debris on the Magnalock and strike armature. Clean as required.
Check for rust on the Magnalock and strike assembly. Clean as required.
8.2 Cleaning Methods
Cleaning once a year is recommended.
Clean every six months where minor rusting occurs.
Clean every three months if rust conditions are severe.
Use a plastic dishwashing scrub pad to aid in the removal of rust.
DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING
DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER
8.2.1 Indoor Applications
Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and
strike plate armature.
8.2.2 Outdoor Applications
Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down
Magnalock and strike plate armature.
Example: Super Lube® Aerosol with SYNCOLON® (PTFE)
Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz.
Phone: (631) 567-5300 / Website: www.super-lube.com
APPENDIX A
Troubleshooting
Problem
Lock Does Not Generate a Magnetic Field
Points of Reference
Check for specified voltage at Magnalock Section
2
Solution
Check for specified current draw at Magnalock
Section 2
Problem
Reduced Holding Force
Points of Reference
Check DC power source is Full-Wave Rectified
(Half-wave Rectifier or AC Power unacceptable)
Section 6.2
Check for specified voltage at Magnalock Section
2
Check for specified current draw at Magnalock
Section 2
Check strike mounting for proper installation
Sections 5.6-5.7
Solution
Check the Magnalock and strike for obstructions
and that contact surfaces are properly cleaned
Section 8
Problem
BondSTAT Does Not Report Secure
Points of Reference
Check for specified voltage at Magnalock Section
2
Check for specified current draw at Magnalock
Section 2
Check strike mounting for proper alignment and
pivoting for proper closure to Magnalock
Table A / Section 5.6.6
Solution
Check the Magnalock and strike for obstructions
and that contact surfaces are properly cleaned
Section 8