5.1.2 EASB-32 Strike Assembly

Re-insert the main housing into the door and insert the anti-rotation pins into the alignment
holes. Install the mounting cap onto the housing using the thread locker compound provided and

tighten thoroughly using an adjustable wrench with a minimum jaw opening of 1-5/16” [33mm].
Install the strike assembly hardware as shown in the Figure 1 Illustration and the Magnalock
Installation Manual
.

5.1.3 EASB-62/82 Door Preparation

Locate and mark the position of the EASB-62/82 on the door. The strike location is determined
by the center position of the lock face. Drill through the door using a 2” [50.8mm] Drill or Hole
Saw. Remove the two (2) screws and Base Plate from the front of the main housing. Insert the
main housing through the door until the anti-rotation pins touch the door face. Place a protective
material over the crown of the housing, to prevent damage to the housing, tap with a hammer
to make center mark drilling locations in the door for the anti-rotation pins. Remove the main

housing from the door and drill the two (2) holes using a 1/8” [3.2mm] drill approximately 1/4”
[6.4mm] deep. Note: See Figure 2 for a concept of a completed installation.

MA

G

N

E

T

ST
R

IK

E

DOOR HEADER

EA
S

B

ANTI-ROTATION

PIN

STOP

BASE

PLATE

1 3/4"

(44.5MM)

THICK

DOOR

OPTIONAL

BRACKETS:

UHB

SFP

WASHER STACK:

STEEL WASHER NEXT TO

EASB FOLLOWED BY TWO

RUBBER WASHERS

APPLY THREAD LOCK

TO ALL THREE

SCREWS

ANTI-ROTATION PIN HOLES (2)

1/8" [3.2mm] x 1/4" [6.4mm] Deep

EASB-62/82

WASHER STACK:

STEEL WASHER NEXT TO

EASB FOLLOWED BY

ONE (1) or TWO (2)

RUBBER WASHERS

Figure 2

5.1.4 EASB-62/82 Strike Assembly

Reinstall the base plate back and two (2) mounting screws onto the housing using the thread
locker compound provided. Tighten thoroughly using a Phillips screwdriver. Install the strike
assembly hardware as shown in Figure 2 and the Magnalock Installation Manual.

6. Thinner and Thicker Door Applications

6.1 EASB-32 Strike Assembly

The EASB-32 is dimensioned to fit a door thickness range from 1.700” [43.2mm] to 2-
1/4”

[57.2mm]. The mounting cap has a threaded body which allows for the variation. The

remaining threads should have a thread locker applied to maintain the installation of the EASB-
32 assembly. The strike mounting screws supplied with the unit come in two (2) lengths. The 2”
[50.8mm] long screw is used for door thicknesses from 1-3/4” to 2” [50.8mm]. The 2-1/4” long
screw is for door thicknesses from 2” to 2-1/4”.

6.2 EASB-62 Strike Assembly

The EASB-62 and EASB-82 have the same body type for installation. It is designed strictly for 1-
3/4” thick doors. If the door is a different thickness, contact the factory. Consider the lock
model, the door type and door thickness when ordering an EASB device.


Note: For thinner doors, Securitron will furnish, upon request, an anti-rotation washer. The
washer installs under the mounting head and keys up to the anti-rotation pins. For thicker
doors, Securitron will furnish, upon request, longer Base Plate mounting screws, an adaptor