beautypg.com

Maintenance, Ransburg, Routine maintenance schedule – Ransburg Evolver Solvent Robot Applicator 79190-XXXXXXXX User Manual

Page 29

background image

MAINTENANCE

Good maintenance is essential to safe and produc-

tive operation. Schedules should be established

by the user, based on the following general infor-

mation and observations of the initial production

requirements. The Ransburg maintenance and

safety information should be made available to

each operator.

Normal fire protection measures are necessary,

including proper storage of paints and solvents

and the proper disposal of waste. Ready access

to appropriate fire extinguishing equipment is

required. For details, consult the appropriate

NFPA safety information, your local fire codes, and

local painting equipment standards. Reference

OSHA, NFPA-33, and your insurance company

information.

ROUTINE MAINTENANCE

SCHEDULE

Follow these maintenance steps to extend the life

of the gun and ensure efficient operation:

Several Times Daily

1. Turn the MicroPak Control Unit

OFF! Follow

Lockout/Tagout procedures.

2. Inspect the fluid nozzle and electrode wire

for paint accumulation. Clean as frequently as

necessary. See "Procedures" in the "Mainte-

nance" section.

>

An electrical discharge or spark may create

an electrical and/or fire hazard during main-

tenance. Do not clean or service the spray

gun with the power supply on. Verify that the

power supply has been locked out and tagged

out per OSHA.

>

Unexpected robot movement can be haz-

ardous. Do not adjust or repair the spray gun

when the robot is operating or waiting to start.

The robot must be locked out and tagged out

per OSHA.

>

Solvents used for equipment flushing must

have flash point ratings equal to or greater than

the flash point rating of the coating material.

Solvents used for general cleaning must have

flash point ratings higher than 100

°

F (37.8

°

C).

>

Never remove spray gun head from

assembly while under pressure.

W A R N I N G

!

>

Take precautions to see that skin is not

punctured by sharp electrode.

W A R N I N G

!

>

Do not bend the gun electrode while wiping.

Never immerse the gun in solvents. This will

cause damage to the electrical components.

C A U T I O N

!

Daily (Or at Shift Start)

1. Turn the MicroPak Control Unit

OFF and:

• Check within 20' (6.1 meters) of the point of

operation (of the gun) and remove or ground

ALL loose or ungrounded containers.

• Inspect workholders for accumulated coating

materials (remove such accumulations if

present).

• Check that the nozzle assembly is clean

and undamaged.

Evolver Solventborne Robotic Atomizers - Maintenance

25

Ransburg

AA-03-02.12