MAINTENANCE
Good maintenance is essential to safe and produc-
tive operation. Schedules should be established
by the user, based on the following general infor-
mation and observations of the initial production
requirements. The Ransburg maintenance and
safety information should be made available to
each operator.
Normal fire protection measures are necessary,
including proper storage of paints and solvents
and the proper disposal of waste. Ready access
to appropriate fire extinguishing equipment is
required. For details, consult the appropriate
NFPA safety information, your local fire codes, and
local painting equipment standards. Reference
OSHA, NFPA-33, and your insurance company
information.
ROUTINE MAINTENANCE
SCHEDULE
Follow these maintenance steps to extend the life
of the gun and ensure efficient operation:
Several Times Daily
1. Turn the MicroPak Control Unit
OFF! Follow
Lockout/Tagout procedures.
2. Inspect the fluid nozzle and electrode wire
for paint accumulation. Clean as frequently as
necessary. See "Procedures" in the "Mainte-
nance" section.
>
An electrical discharge or spark may create
an electrical and/or fire hazard during main-
tenance. Do not clean or service the spray
gun with the power supply on. Verify that the
power supply has been locked out and tagged
out per OSHA.
>
Unexpected robot movement can be haz-
ardous. Do not adjust or repair the spray gun
when the robot is operating or waiting to start.
The robot must be locked out and tagged out
per OSHA.
>
Solvents used for equipment flushing must
have flash point ratings equal to or greater than
the flash point rating of the coating material.
Solvents used for general cleaning must have
flash point ratings higher than 100
°
F (37.8
°
C).
>
Never remove spray gun head from
assembly while under pressure.
W A R N I N G
!
>
Take precautions to see that skin is not
punctured by sharp electrode.
W A R N I N G
!
>
Do not bend the gun electrode while wiping.
Never immerse the gun in solvents. This will
cause damage to the electrical components.
C A U T I O N
!
Daily (Or at Shift Start)
1. Turn the MicroPak Control Unit
OFF and:
• Check within 20' (6.1 meters) of the point of
operation (of the gun) and remove or ground
ALL loose or ungrounded containers.
• Inspect workholders for accumulated coating
materials (remove such accumulations if
present).
• Check that the nozzle assembly is clean
and undamaged.
Evolver Solventborne Robotic Atomizers - Maintenance
25
Ransburg
AA-03-02.12