Ransburg, Evolver gun selection guide (cont.) – Ransburg Evolver Solvent Robot Applicator 79190-XXXXXXXX User Manual
Page 15
EVOLVER GUN SELECTION GUIDE (Cont.)
Table FF = Cable & Tubing Manifold Configuration
00 = Gun Only (No cable or manifold)
23 = No Cable (English tubing manifold)
24 = No Cable (Metric tubing manifold)
For Use W/Power Supply Configuration 3 or 4:
English
Metric
01 = 25' Cable (one-piece cable)
12 = 7.6m Cable (one-piece cable)
02 = 50' Cable (one-piece cable)
13 = 15.2m Cable (one-piece cable)
03 = 75' Cable (one-piece cable)
14 = 22.9m Cable (one-piece cable)
04 = 100' Cable (one-piece cable)
15 = 30.5m Cable (one-piece cable)
05 = 15' Cable to Junction Box; 15' Cable to Robot 16 = 4.6m Robot to Junction Box; 4.6m Cable to Robot
06 = 40' Cable to Junction Box; 15' Cable to Robot 17 = 12.2m Cable to Junction Box; 4.6m Cable to Robot
07 = 60' Cable to Junction Box; 15' Cable to Robot 18 = 18.3m Cable to Junction Box; 4.6m Cable to Robot
08 = 75' Cable to Junction Box; 15' Cable to Robot 19 = 22.9m Cable to Junction Box; 4.6m Cable to Robot
09 = 25' Cable to Junction Box; 25' Cable to Robot 20 = 7.6m Cable to Junction Box; 7.6m Cable to Robot
10 = 50' Cable to Junction Box; 25' Cable to Robot 21 = 15.2m Cable to Junction Box; 7.6m Cable to Robot
11 = 75' Cable to Junction Box; 25' Cable to Robot 22 = 22.9m Cable to Junction Box; 7.6m Cable to Robot
For Use W/Power Supply Configuration 1 or 2:
English
Metric
31 = 25' Cable (one-piece cable)
51 = 7.6m Cable (one-piece cable)
32 = 50' Cable (one-piece cable)
52 = 15.2m Cable (one-piece cable)
33 = 75' Cable (one-piece cable)
53 = 22.9m Cable (one-piece cable)
34 = 100' Cable (one-piece cable)
54 = 30.5m Cable (one-piece cable)
35 = 15' Cable to Junction Box; 15' Cable to Robot 55 = 4.6m Cable to Junction Box; 4.6m Cable to Robot
36 = 40' Cable to Junction Box; 15' Cable to Robot 56= 12.2m Cable to Junction Box; 4.6m Cable to Robot
37 = 60' Cable to Junction Box; 15' Cable to Robot 57 = 18.3m Cable to Junction Box; 4.6m Cable to Robot
38 = 75' Cable to Junction Box; 15' Cable to Robot 58 = 22.9m Cable to Junction Box; 4.6m Cable to Robot
39 = 25' Cable to Junction Box; 25' Cable to Robot 59 = 7.6m Cable to Junction Box; 7.6m Cable to Robot
40 = 50' Cable to Junction Box; 25' Cable to Robot 60 = 15.2m Cable to Junction Box; 7.6m Cable to Robot
41 = 75' Cable to Junction Box; 25' Cable to Robot 61 = 22.9m Cable to Junction Box; 7.6m Cable to Robot
Table G = Power Supply Configuration
0 = No Power Supply
1 = A10406-01 Power Supply Enclosure with one MicroPak and one Discreet I/O Card
2 = A10406-01 Power Supply Enclosure with two MicroPaks and two Discreet I/O Cards
3 = One LECU5004-31 MicroPak (FM Approved)
4 = One LECU5004-11 MicroPak (Not FM Approved)
79190 - A B C D E FF G
Evolver Solventborne Robotic Atomizers - Introduction
11
Ransburg
AA-03-02.12