Test and maintenance kit usage (79870-00), Ransburg, Vector solo aa90 applicators - maintenance – Ransburg Vector Solo AA90 79698 User Manual
Page 41

Vector Solo AA90 Applicators - Maintenance
Ransburg
37
AH-08-04.2
TEST AND MAINTENANCE
KIT USAGE (79870-00)
Figure 66: 79870 Test and Maintenance Kit
1
2
3
4
5
6
79870 TEST AND
MAINTENANCE KIT
Item#
Brass Tee Fitting
100 psi Pressure Gauge
6" Air Hose Assembly
Left Hand Male Fitting
Barb Fitting
Tubing
Description
The 79870 Test and Maintenance Kit allows the
user to determine the inlet pressure at the base
(handle) of the Vector Solo hand-held applicators.
The Test and Maintenance Kit also allows the user
to test the 79835 Power Module Assembly on the
Vector Solo applicator.
The procedure to test the inlet pressure at the
base (handle) of the Vector Solo applicator is as
follows (see Figures 66 and 67):
1. Connect the left-hand fitting of the 79727 Air
Hose to the male inlet of the Test and Maintenance
Kit.
2. Connect the 6" air hose assembly between the
brass tee fitting and the gun air inlet.
3. Install the 1/4 module into the 3/4 module and
tighten the two (2) screws.
Figure 64: Module Assembly
4. Install power module to handle and tighten
three (3) screws. Reinstall the fluid line.
Figure 63: Fluid Fitting Replacement
Figure 65: Power Module Assembly
2. Install the fluid fitting.
C W
3
6
5
2
4
1