Applicator repair, Ransburg – Ransburg Vector Solo AA90 79698 User Manual
Page 27
Vector Solo AA90 Applicators - Maintenance
Ransburg
23
AH-08-04.2
DO NOT allow the fluid lines to stand
empty without flushing first! This will cause
dried paint flaking and clogging of the fluid
lines, applicator passages, and/or nozzles.
All repairs should be made on a clean, flat sur-
face. If a vise is used to hold parts during service
or repair, DO NOT clamp onto plastic parts and
always pad the vise jaws!
The following parts should be thoroughly packed
with dielectric grease (LSCH0009-00) leaving
NO
air space or voids when assembling:
• All O-Rings (Teflon o-rings do not need
lubrication)
• Needle Shaft Assembly
• Packing Tube
• Cascade and Barrel
Equipment Required
• Special Multi-Purpose Wrench (79854-00) *
• 4mm, 3mm, and 2.5mm Allen Wrenches *
• Screwdriver (blade)
• Jam Nut Removal Tool (79793-00) *
• Dielectric Grease (LSCH0009-00) *
• Sealant, Medium Strength (7969-10)
• Dowel, 6mm (1/4") diameter
• Air Cap Removal Tool (79642-00) *
• 2.5mm Wrenches (two) (74133-00) *
• Nozzle Wrench (76428-00) *
Note: *Supplied with applicator
APPLICATOR REPAIR
Figure 17: kV Probe
There is a 10 giga ohm resistor in the
probe that lowers the output voltage. The
maximum kV rating is at no load. Paint
overspray and other contaminates on the
barrel will lower the kV probe reading.
NOTE
4. Using the meter set to kV, measure the output
voltage of the applicator. Voltage output reading
is between 67 and 75kV.
5. See "Troubleshooting" in the "Maintenance"
section for possible cause of poor performance.
C A U T I O N
!
1 - Full Voltage Setting
2 - 76667-00 kV Probe
3 - 76634-00 Meter