Vector Solo AA90 Applicators - Operation
Ransburg
15
AH-08-04.2
1. Ensure the On/Off switch is in the desired po-
sition for voltage.
Figure 6: Voltage On/Off Position
2. Ensure the voltage high/low switch is in the
desired position.
Figure 7: High/Low Voltage Selection
3. Open the fluid supply - 207 bar (3000 psig )
maximum working pressure.
SAFE OPERATION
• Ground all operators by requiring that they hold
the applicator handle with a bare hand.
• Ground operators and all other persons in spray
areas by requiring that they wear conductive
soled shoes or grounding straps.
• Have exhaust fans operating while spraying.
• Exhaust fans must be interlocked with the at-
omization air.
• See that no more than one gallon of solvent per
safety container per operator is inside of the
hazard location.
• If
ANY symptom of improper operation occurs,
suspend use of the unit until the problem has
been diagnosed and corrected. See "Trouble-
shooting Guide" in the "Maintenance" section
or contact your authorized Ransburg repre-
sentative.
• Ground
MUST be maintained during the addi-
tion of fluid to any supply container! Whenever
transferring flammable fluid from one container
to another, both containers
MUST be properly
connected to a proven ground first and then to
each other. Personnel executing such a transfer
MUST also be grounded.
• A chemical reaction resulting in the possibility
of a pressure
EXPLOSION, may occur if 1,
1, 1-Trichloroethane, Methylene Chloride, or
other Halogenated Hydrocarbon solvents are
used in
PRESSURIZABLE FLUID SYSTEMS
having
ALUMINUM or GALVANIZED WETTED
PARTS. Such an explosion could cause DEATH,
serious
BODILY INJURY and/or substantial
property damage. Consult your fluid supplier to
determine the chemical content of your solvents.
(See "HHC Explosion Hazard Danger Sign" and
"Halogenated Hydrocarbon Safety Bulletin".)
• Never flush the applicator with solvent while
electrostatics are on. Failure to turn off electro-
statics while flushing may cause an
IGNITION
HAZARD. Applicator supply air must be inter-
locked with solvent supply.
V O L T A G E O F F
V O L T A G E O N
6 0 % V O L T A G E
1 0 0 % V O L T A G E
OPERATION