Installation, 79900 solo solventborne installation, Ransburg – Ransburg Vector Solo 79900 Solventborne RS90-AS User Manual
Page 17
Vector Solo Applicators - Installation
INSTALLATION
Air Hose
13
Fluid Hose Recommendation
Ransburg recommends using a 79548 Fluid Hose
Assembly. This assembly is made to specifically
fit the fluid fitting size engineered into the applica-
tor. This hose is available from your authorized
Ransburg distributor. Available hose lengths are
listed in "Accessories" in the "Parts Identification"
section of this manual.
Any user installed fluid hose used must
be rated for 100 psig (6.9 bar) working
pressure minimum.
C A U T I O N
!
Filters
1. Install an air filter assembly on the outlet of the
main air regulator. The filter should be 5 micron
with a maximum working pressure of at least 100
psig (6.9 bar). For Class 3 air quality, which is a
5 micron size and has a dew point of -4F (-20C),
the relative humidity (RH) of the air should be 5%.
Screw the fitting into the filter inlet. The filter MUST
be installed with the arrow pointing in the direction
of flow. (Refer to the appropriate Filter Assembly
manual for Installation Instructions.)
2. Ransburg recommends that a fluid filter be in-
stalled at the output of the fluid supply (pressure
pot, pump, circulating system, etc.). It is the end
user's responsibility to install the proper filter that
meets their system's requirements.
79900 SOLO
SOLVENTBORNE
INSTALLATION
The user
MUST read and be familiar
with the "Safety" section of this manual.
This hand held device is intended to be
used by trained personnel ONLY.
This manual
MUST be read and thor-
oughly understood by
ALL personnel who
operate, clean, or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements for operat-
ing and servicing safely are followed. The
user should be aware of and adhere to
ALL
local building and fire codes and ordinanc-
es as well as NFPA, OSHA, and all related
country safety codes prior to installing, op-
erating, and/or servicing this equipment.
Personnel
MUST be GROUNDED to
prevent a shock or spark during electrostat-
ic operation.
Install and route the hoses so they are
NOT exposed to temperatures in excess of
120° F and so that all hose bends are
NO
LESS than a 6-inch (15cm) radius. Fail-
ure to comply with these parameters could
cause equipment malfunction that might
create
HAZARDOUS CONDITIONS!
W A R N I N G
!
For proper safe function of the applica-
tor, the 79727-XX Air Hose Assembly must
be used (either standard or quick discon-
nect style).
W A R N I N G
!
Ransburg