Fairbanks H90-5200-A Digital Instrument User Manual
Page 31

* All commands must be terminated by a
command will be executed.
* The Command String (including the
be longer than 20 characters. IF the string is longer than 20 characters, the extra
characters will be lost.
* If a Scale ID other than 0 (Section 2, B-13) has been entered, the Command
must be preceded by a 1-3 digit Scale ID or it will be ignored. If a Scale ID other than
0 has been entered and weight is outputted, the weight output string will be preceded
by a Scale ID String.
* Buffer will be cleared after command is executed.
* Computer commands may be echoed and /or acknowledged. Refer to Subsection I,
of this section for further information.
Example
Command
:
Response
:
SCALE 12
Weight is output to all printer channels The following computer commands are
supported. Refer to Appendix V (Data Format) for output string information.
Weight is output to all printer channels
WEIGHT
Weight is output to computer channel requesting data only L(LB)
OR K(KG) can be used to request output in specific weight unit
ZERO
Scale is zeroed IF no motion
NET
Scale is switched to net mode IF tare is enabled
GROSS
Scale is switched to gross mode
AUTOTARE
Scale is Autotare IF Autotare is enabled
START
Batch cycle is started
STOP
DISCHARGE
50515
31