E. Avoid contact with skin, eyes and clothing. Protective equipment should be worn at all times.
During clean-up of spilled MEKP, personal safety equipment, gloves and eye protection must be
worn. Fire fighting equipment should be at hand and ready.
F. Avoid spillage, which can heat up to the point of self-ignition.
G. Repair any leaks discovered in the catalyst system immediately, and clean up the leaked
catalyst at once in accordance with the catalyst manufacturer’s instructions.
H. Use only original equipment or equivalent parts from Magnum Venus Plastech in the catalyst
system (i.e.: hoses, fitting, etc.) because a dangerous chemical reaction may result between
substituted parts and MEKP.
I. Catalyst accumulated from the purging of hoses or the measurement of fluid output deliveries
should never be returned to the supply tank, such catalyst should be diluted with copious
quantities of clean water and disposed of in accordance with the catalyst manufacturer’s
instructions.
The extent to which the user is successful in accomplishing these ends and any additional
recommendations by the catalyst manufacturer determines largely the safety that will be present
in his operation.