MAINTAINENCE AND REPAIR MANUAL

UPLS-2400-SS/2300-SS

MAGNUM VENUS PLASTECH

REV 1.13

APRIL 2010

PAGE 19


Remove the 4 Hex Nuts, Foot Valve Collar and Foot Valve from the bottom of the Fluid Section. Note the
orientation of the Foot Valve inlet relative to the Outlet Body for assembly purposes. (FIG 3.2)

FIG 3.20

Remove the Cylinder and remove the two O-rings and discard. (FIG 3.21)

FIG 3.21

Remove the 4 Cylinder Tie Rods from the Outlet Body. (FIG 3.22)

FIG 3.22