Magnum Venus Plastech UltraMAX UPLS-2300_UPLS-2300-SS User Manual
Page 18

MAINTAINENCE AND REPAIR MANUAL
UPLS-2400-SS/2300-SS
MAGNUM VENUS PLASTECH
REV 1.13
APRIL 2010
PAGE 18
FLUID SECTION DISASSEMBLY PROCEDURE
Using a table mounted vise, clamp the Outlet Body between the jaws as illustrated (Fig. 3.0)
FIG 3.0
Remove the Rod Adapter, leaving the Hex Nut, and the Ball Joint Rod End in place. (FIG 3.1)
•
Caution: If the Hex Nut, and the Ball Joint Rod End have to be removed, carefully measure the
distance from the end of the Ball Joint Rod End to the top of the Rod Adapter to insure that it is
installed back in the same position. If this is not put back to factory specifications(2 threads
showing), damage to the Chrome Ball, Foot Valve Spring and the Ball Stop can result. (FIG 3.11)
FIG. 3.10
FIG. 3.11