MAINTAINENCE AND REPAIR MANUAL

UPLS-2400-SS/2300-SS

MAGNUM VENUS PLASTECH

REV 1.13

APRIL 2010

PAGE 18

FLUID SECTION DISASSEMBLY PROCEDURE

Using a table mounted vise, clamp the Outlet Body between the jaws as illustrated (Fig. 3.0)

FIG 3.0

Remove the Rod Adapter, leaving the Hex Nut, and the Ball Joint Rod End in place. (FIG 3.1)

Caution: If the Hex Nut, and the Ball Joint Rod End have to be removed, carefully measure the

distance from the end of the Ball Joint Rod End to the top of the Rod Adapter to insure that it is

installed back in the same position. If this is not put back to factory specifications(2 threads

showing), damage to the Chrome Ball, Foot Valve Spring and the Ball Stop can result. (FIG 3.11)

FIG. 3.10

FIG. 3.11