PISTON ROD ASSEMBLY


Place the Piston Rod into the vise using the flats at the top of the rod. Placing it vertically in the vise will
aid in installation.

Insert the Piston Ball Spring into the end of the Piston Rod and place over the dowel pin, and then place
the Chrome Ball on top of the Piston Ball Spring.

Caution: Do not drop or dent this ball as it will be permanently damaged and must be replaced

Note: If the Fluid Section is to be used with a Polyester/Vinylester resin system then a fine coat of
Red Grease should be applied to the Chrome Ball before installing into the Piston Rod. The
Chrome Ball on an Epoxy or Urethane system should be clean and in good condition with no
lubricant or grease. If in doubt contact the material manufacturer for recommendations.