Daily Start-up & Shut-Down:

DAILY STARTUP

1.

Check and refill all components and materials.


2.

Close the relief valve on the flush tank lid.


3.

Open the lockout ball valve (7702-2-2) to pressure up the system. Bleed off any water,
check the system for leaks and damage, replace or repair items as needed.


6.

Check that ram pressure settings and pump pressure settings are set to the
appropriate settings. If needed press and hold the priming button and adjust the
adhesive pump pressure.


7.

Remove the night cap plug (HOD-1002) if it is installed.


8.

Apply a small amount of red grease (7607-2-1) to the threads of the dispensing head.


8.

Reassemble and attach static mixer assembly.


9.

Check flush system for proper operation.


The system is ready for use.


DAILY SHUT-DOWN

1.

Drain water trap filter daily.


2.

Thoroughly flush and the dispensing head.


3.

Remove static mixer tube and push the four static mixers (05271) out of tube.


4.

Thoroughly clean mixers and mix tube with solvent.


5.

Wipe clean the front of the dispense head and check any damage.


6.

Close the main lockout ball valve (7702-2-2) to relieve air pressure from the system.


7.

Lift the relief valve on the flush tank lid to release flush tank pressure.


8.

Install night cap plug (HOD-1002) to the front of the dispensing head.


NOTE: Do not leave barrel piston in 55-gallon (200 liter) drum if the system will be idle

for more than two weeks.