UltraBond 10:1 Operations Manual

Rev. 12/2012

Page | 34

6.

Adjust pressure regulator marked Air Life to 20 psi

7.

Hold drum down if it beings to lift, close and open the ram control lever intermittently to raise
follower and pump out of drum.


8.

It may be necessary to adjust both ram / air lift and ram extraction pressures accordingly to
necessitate removal without lifting the drum / pail.

9.

After pump and follower are removed, inspect, seal and dispose of protector gasket

10.

Clean any buildup of material on follower gasket as well as follower plate

11.

Replace with “new” drum and refer back to procedures for priming new drum.

Note: the procedures will be the same for changing the Activator pail only using the
controls related to the Activator Ram pump (see figure 51).



















Fig. 51














Activator Ram control valve and
Ram / Air Lift gauge and regulator.

Activator Ram Extraction
pressure gauge and
regulator