beautypg.com

Decoding part number – Liquid Controls SP2200 User Manual

Page 4

background image

2

Example: SP2200 A 3

A

Series:
6 digits counter, 5 digit ratemeter

with presets and scaling.

Operating Voltage:

110 = 110 VAC

±

15% or 12 to 15 VDC

220 = 220 VAC

±

15% or 12 to 15 VDC

24 = 24 VAC

±

15% or 12 to 15 VDC

Count Inputs:

3 =

Standard, 4-30 VDC simultaneous inputs.

3M =

Mag. Input, Input A only, 30mV input
(Input B, 4-30V)

3MB = Mag. Input, Inputs A & B, 30mV input

Options

1= RS232 Communications
2= RS422 Communications
A= Analog Output (4-20/0-20 mA)
CE = CE Approved Version

NOTE: RS232/RS422 & Analog Output options can not be combined

DECODING PART NUMBER

LOCKOUT
Unauthorized front panel changes can be prevented by entering a
user selected 5 digit code. The front panel can be completely
locked out or the presets can remain accessible.

RATEMETER
Accurate to 4 1/2 digits (

±

1 display digit). The ratemeter uses 1/tau

with 8 digit math, can sample from 2 to 24 seconds maximum, and
auto-range up to 5 digits of significant information. In the “RPS”
mode, the ratemeter displays in units per second, and in the
“scale” mode, units per hour or per minute. The unit will display the
rate of the A&B Inputs.

COUNTER
The two 6-digit counters can count at 10Khz speed. Each has a
seporate 5-digit dividing scale factor. The counters advance on the
positive edge of each pulse. Besides being able to step through the
total and rate values of A & B inputs, the user can see a selected
combination of total or rate of A+B, A-B, A

÷

BX100 (percent of A to

B), A

÷

A+BX100 (percent of A to total). A negative display will be

veiwed as a 5 digit display with a negative symbol ( -

12345

).

SPECIFICATIONS

(continued)